Frigidaire fefb9100es0 Installationsanweisungen

Seite von 16
8
                         GAS CONNECTION
1.  Remove the shipping cap from gas pipe at the rear of the dryer.
NOTE: DO NOT connect the dryer to L.P. gas service without converting
      the gas valve. An L.P. conversion kit must be installed by  a
            qualified gas technician.
2.  Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved pipe from gas
supply line to the 3/8 inch (0.96 cm) pipe located on the back of the
dryer (see pages 6 and 7). Use a 1/2 inch to 3/8 inch (1.27 cm to 0.96
cm) reducer for a connection. Apply an approved thread sealer that is
resistant to the corrosive action of liquefied gases on all pipe connections.
3.  Open the shutoff valve in the gas supply line to allow gas to flow
     through pipe.
4.  Test all connections by brushing on a soapy water solution. NEVER test
for gas leaks with an open flame.
                     GENERAL INSTALLATION
1. Connect the exhaust duct to outside exhaust system (see pages 3 and
4).  Use duct tape to seal all joints.
2. With the dryer in its final position, adjust one or more of the legs until
the dryer is resting solid on all four legs. Place a level on top of the dryer.
The dryer MUST be level and resting solid on all four legs.
3. Plug the power cord into a grounded outlet. NOTE: Check to ensure
the power is off at circuit breaker/fuse box before plugging the power
cord into the outlet.
4. Turn on the power at the circuit breaker/fuse box.
 Before operating the dryer, make sure the dryer area is
clear and free from combustible materials, gasoline, and other
flammable vapors. Also see that nothing (such as boxes, clothing,
etc.) obstructs the flow of combustion and ventilation air.
5. Run the dryer through a cycle check for proper operation.
NOTE:  On gas dryers, before the burner will light, it is necessary for the
       gas line to be bled of air. If the burner does not light within 45
       seconds the first time the dryer is turned on, the safety switch
             will shut the burner off. If this happens, turn the timer to "OFF"
       and wait 5 minutes before making another attempt to light.
6. If your dryer does not operate, please review the "Avoid Service Check-
list" located in your Use and Care Guide before calling for service.
7. Place these instructions in a location near the dryer for future reference.
NOTE:
A wiring diagram is located inside the dryer console or under the
top panel.
                          REPLACEMENT PARTS
Pedestal
A pedestal accessory, Model No.  NLPWD15, specifically designed for this
dryer may be used when elevating the dryer for ease of use.  Failure to use
accessories certified by the manufacturer could result in personal injury,
property damage or damage to the dryer.
If replacements parts are needed for your dryer, contact the source where
you purchased your dryer, call 1-800-944-9044, or visit our website,
www.frigidaire.com, for the Frigidaire Company Authorized Parts Distributor
nearest you.
 Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation. Verify proper
operation after servicing.
 Destroy the carton and plastic bags after the dryer is unpacked.
Children might use them for play. Cartons covered with rugs, bedspreads,
or plastic sheets can become airtight chambers causing suffocation. Place
all materials in a garbage container or make materials inaccessible to
children.
 The instructions in this manual and all other literature included
with this dryer are not meant to cover every possible condition and situation
that may occur. Good safe practice and caution MUST be applied when
installing, operating and maintaining any appliance.
VALVE OPEN / GAS FLOW POSITION
                                    Non Canadian ELECTRIC Dryer
1. Remove the screws securing the terminal block access cover and the
strain relief mounting bracket located on the back of the dryer upper
corner.
2. Install a U.L. approved strain relief in the entry hole of the mounting
bracket. Finger tighten the nut only at this time.
3. Remove the ground wire from the green ground screw located above
the terminal block.
4. Thread a U.L. approved 30 amp power cord, NEMA 14-30 type ST or
SRDT through the strain relief.
5. Attach the green power cord ground wire to the cabinet with the green
ground screw.
6. Attach the white (neutral) power cord conductor from the power cord
and the neutral ground wire from the dryer harness to the silver-colored
center terminal on the terminal block. Tighten the screw securely.
7. Attach the red and black power cord conductors to the outer brass-
colored terminals on the terminal block.
    
  Do not make a sharp bend or crimp wiring/ conductor at the
                          connections.
8. Tighten the screws securing the cord restraint firmly against the power
cord.
9. Tighten the strain relief nut securely so the strain relief does not turn.
10. Reinstall the terminal block access cover
.
STRAIN
RELIEF
MOUNTING
BRACKET
NUT
TIGHTEN
NUT
TO THESE
THREADS
POWER
CORD
RED
WHITE
BLACK
TERMINAL BLOCK
SILVER TERMINAL
GREEN
GROUND
SCREW
GREEN POWER CORD
GROUND WIRE
NEUTRAL
GROUND
WIRE
ELECTRICAL CONNECTIONS
FOR 4-WIRE SYSTEM
RED
BLACK
WHITE
GREEN
30 AMP NEMA 14-30 TYPE SRDT OR ST
TYPICAL 4
CONDUCTOR
TYPICAL 4
CONDUCTOR