Seite von 20
GAS COOKTOP INSTALLATION INSTRUCTIONS
2
Figure 2 – COUNTERTOP CUTOUT OPENING
To eliminate the risk of
burns or fire by reaching over heated
surfaces, cabinet storage space located
above the cooktop should be avoided. If
cabinet storage is provided, risk can be
reduced by installing a range hood that
projects horizontally a minimum of 5"
(12.7 cm) beyond the bottom of the
cabinets.
Min.
Dimensions 
J
 is the Minimum
Distance Required Between Rear
of Cooktop and Adjacent
Combustible Surfaces.
18" Min.
(45.7cm Min.)
Clearance
30" (76.2 cm) Min.
Clearance Between
the Top of the
Cooking Platform
and Unprotected
Wood or Metal
Cabinet
24" (61 cm)
Min. when
Bottom of Wood or
Metal Cabinet is
Protected by Not
Less Than 1/8"
Flame Retardant
Millboard Covered
with Not Less Than
N0.28 MSG Sheet
Steel, 0.015" (0.04
cm) Stainless Steel,
0.024" (0.06 cm)
Aluminum or
0.020" (0.05 cm)
Copper.
24" (61 cm)
13" (33 cm)
Max. Depth For
Cabinet Installed
Above Cooktop.
Dimension 
H
 is the
Minimum Clearance
Required From Right
Side of Cooktop To
Adjacent Combustible
Surface.
Dimension 
K
 is the
Minimum Clearance
Required From Left
Side of cooktop To
Adjacent Combustible
Surface.
Drawers Cannot Be Used With This
Cooktop Since Burner Box Extends
3" (7.6 cm) Below Surface of
Countertop.
MODEL
H
J
K
30" Models
4" (10.2 cm)
1 1/2" (3.8 cm)
6" (15.2 cm)