Frigidaire FPEF4085KF Installationsanweisungen

Seite von 16
3
40" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
NOTE: Range is shipped from factory with 1 1/8" dia. hole 
as shown in figure 3. If a larger hole is required, punch out 
the knockout.
Model and Serial Number Location
The serial plate is located on the oven front frame behind 
the large oven door.
When ordering parts for or making inquiries about your 
range, always be sure to include the model and serial 
numbers and a lot number or letter from the serial plate 
on your range (Figure 1).
Serial Plate Location
1.
 Power Supply Cord Kit
The user is responsible for connecting the power supply 
cord to the connection block located behind the back 
panel access cover.
This appliance may be connected by means of 
permanent "hard wiring"; flexible armored or 
nonmetallic shielded copper cable (when local code 
allow it) or by means of a power supply cord kit.
 Risk of fire or electrical shock exists 
if an incorrect size range cord kit is used, the 
Installation Instructions are not followed, or the 
strain relief bracket is discarded.
For mobile homes, new installations or recreational 
vehicles, use only a power supply kit designed for a 
range at 125V/250V 50A recommended (minimum 
40A). Cord must have either 3 (when local code permits 
grounding through neutral) or 4 conductors. Terminal on 
end of wires must be either closed loop or open spade 
lug with upturned ends. Cord must have strain-relief 
clamp.
 Do not loosen the nuts which secure 
the factory-installed range wiring to terminal block 
while connecting range. Electrical failure or loss of 
electrical connection may occur.
2. 
Access to Terminal Block & 
Grounding Strap
Electrical Shock Hazard
• Electrical ground is required on this appliance.
• Do not connect to the electrical supply until
appliance is permanently grounded.
• Disconnect power to the circuit breaker or fuse
box before making the electrical connection.
•  This appliance must be connected to a grounded,
metallic, permanent wiring system, or a 
grounding connector should be connected to the 
grounding terminal or wire lead on the appliance.
Failure to do any of the above could result in a 
fire, personal injury or electrical shock.
Figure 2
Figure 1
To gain access to lower terminal 
block bend lower back cover plate 
along row of holes shown here
 This appliance is manufactured with 
the frame grounded by connection of a grounding 
strap between the neutral power supply terminal 
and the frame. If used in USA, in a new branch 
circuit installation (1996 NEC), mobile home or 
recreational vehicle, where local code do not 
permit grounding through neutral (white) wire 
or in Canada; remove the grounding strap from 
the frame and cut the other end, near the neutral 
terminal. Connect the appliance in usual manner.