Configuring I/O Modules
Extreme Networks Consolidated "i" and "e" Series Hardware Installation Guide
271
NOTE
If congestion is detected on a port with flow control enabled, a flow control PAUSE frame is sent out 
that port. The PAUSE frame is not sent out on the other port in the group.
Table 56 describes the media types and the associated maximum distances for the GM-16X
3
 module.
Mini-GBIC Ports
The G16X
3
 module supports any of the following mini-GBICS:
SX mini-GBIC
LX mini-GBIC
ZX mini-GBIC
NOTE
For more information about the supported mini-GBIC types, see “Mini-GBIC Types” on page 23.
LEDs
The G16X
3
 module has the following LEDs:
Module status
Port status
Diagnostics
For information about the LEDs and their activity on the G16X
3
Software Requirements 
The G16X
3
 module requires ExtremeWare version 7.0.1b11 or later and BootROM 7.8 or later.
Hardware Requirements
Extreme Networks recommends using iPower power supplies (part numbers 50020, 50021, 50022) with 
F96Ti modules in a BlackDiamond 6800 chassis. A BlackDiamond 6800 chassis with the original power 
supplies (part number 50012) will power fewer G16X
3
 modules than a chassis with iPower power 
supplies.
Table 56: G16X
3
 media types and distances
Mini-GBIC Type
Media Type
Maximum Distance 
(meters)
1000BASE-SX
multimode fiber
550 
1000BASE-LX
single-mode fiber
10,000
1000BASE-ZX
single-mode fiber
70,000