Intermec 6100 Verweisanleitung

Seite von 328
SECTION 5
Communications and Device Support
5-14    PEN*KEY
R
 6100 Computer Programmer’s Reference Guide
Table 5Ć4 
NRInet Protocol Errors
Error # Meaning
0
No error.
1
PSROBOC.EXE could not be loaded.  Ensure the directory for PSROB0C.EXE is in the PATH.
6
User aborted communications by pressing [NO].
11
An invalid parameter was specified in the control file.
800
TCP/IP kernel could not be loaded.  Possible causes for this are:
(PSROM0C V2.XX only)  NET.CFG or PCTCP.INI does not exist.
(PSROM0C V2.XX only)  The PCTCP environment variable is not set.
The PATH does not include the directories of the drivers.
The computer does not have an Ethernet ID or the Ethernet ID could not be accessed.
(PSROM0C V3.XX only)  Invalid client IP address.  Verify the IPCLIENT parameter, or 
make sure the DHCP or BOOTP server is running.
801
Invalid client IP address.  
For PSROM0C V2.XX, verify the entry for `ipĆaddress' in PCTCP.INI, or ensure the DHCP or
BOOTP server is running.
For PSROM0C V3.XX, verify the IPCLIENT parameter, or ensure the DHCP or BOOTP server
is running.
802
(PSROM0C V2.XX only) Invalid Service or Service Type, or invalid port number.  Verify the
`etcĆdir' entry in PCTCP.INI specifies the correct path for the SERVICES file, and that an entry
exists for `nrinet.'
803
Invalid host name or IP Address.  Ensure the host computer is running.
For PSROM0C V2.XX only, verify the IPHOST parameter and the entries for `subnetĆmask,'
`router,' `domain,' and `domainĆnameĆserver' in PCTCP.INI.
For PSROM0C V3.XX, verify the IPHOST, NETMASK, and ROUTER parameters.
804
(PSROM0C V2.XX only)  Could not create socket.  Check all cables and network connections.
806
Block sent was incomplete, or block received was incomplete.
807
Client/server negotiation failed.
808
Server specified an unsupported block size.
809
Invalid buffer pointer.
810
All server connections are already in use.  Try again later.
811
Timeout while sending data.  Connection to remote machine dropped.  Ensure host is still
running; check all cables and network connections.
812
Timeout while receiving data.  Connection to remote machine dropped.  Ensure host is still
running; check all cables and network connections.
813
(PSROM0C V2.XX only)  Attempt to send data to the server failed due to a closed connection.
Ensure server is still running, and check all cables and network connections.
814
Attempt to receive data from the server failed due to a closed connection.  Ensure server is still
running, check all cables and network connections.
815
Could not access the network attach information.  Ensure the Access Point, such as 6710, is
connected and running.
816
An error occurred reading the network attach information.  Ensure the Access Point, such as
6710, is connected and running.
817
Server did not respond to the connect request.  Ensure the server is still running, and check all
cables and network connections.
818
An error occurred reading the TCP/IP kernel information.
935
Client/server negotiation failed.
939
Destination address required.
940
Message too long.
948
Address already in use.
5. Communications
and Device Support