Intermec cv60 Zusätzliches Handbuch

Seite von 12
4
Mobile DC-DC Uninterruptible Power Supply Installation Guide
Connecting the UPS (Smart Mode)
Note: Remove the dust cover from the serial port
before connecting the cable.
1 Attach the RSĆ232 cable (PN 321-593-001) to COM1 or
COM2 on the CV60 and tighten the screws to the DBĆ9
connector.
2 Connect the other end of the RSĆ232 serial cable to the
RS-232 connector on the UPS and tighten the screws.
3 Connect the cable from the UPS power OUT to the CV60
power input connector. Tighten the connector.
4 Connect the cable (PN 226-341-003, six foot cable or PN
226-341-004, three foot cable) from the vehicle battery or
power supply to the dc input connector on the UPS.
Connecting the UPS (Standard)
1 Connect the cable (PN 226-341-003, six foot cable or PN
226-341-004, three foot cable)  from the vehicle battery or
dc-dc converter to the dc input connector on the UPS.
2 Connect the cable from the UPS power OUT to the CV60
power input connector. Tighten the connector.
Power/Charge Status LED
The LED lights when power is applied to the UPS.
S Amber: indicates UPS is charging
S Red: indicates UPS is discharging
S Green: indicates UPS is charged.
Note: Always have power to the UPS before booting
the CV60. Failure to do so may cause the UPS to
shut down.