Intermec 1552 Zusätzliches Handbuch

Seite von 8
Part No. 067673-003
1
Sabre Battery Pack Instructions
The Sabre
 nickel-metal-hydride (NiMH) battery pack (Part No. 070066) is designed
for use in the Sabre 1552 laser scanner.
Caution
The nickel-metal-hydride (NiMH) batteries used in this device may present a fire or
chemical burn hazard if mistreated. Do not disassemble, heat above 100°C (212°F), or
incinerate.
Conseil
La batterie d’NiMH utilisée dans ce périphérique peut causer des risques d’incendie ou
de brûlures chimiques si elle n’est pas utilisée correctement. Eviter de défaire, de
chauffer à plus de 100°C (212°F) ou de brûler.
Charging the Battery Pack
To fully charge the battery packs, allow several cycles (using the battery packs
followed by charging them) for the battery packs to be fully charged.
To reach full capacity, you must charge your NiMH battery pack for 24 hours prior to
using it for the first time. The light will turn green before the time is up but continue to
charge the battery pack for the full 24 hours to reach full capacity.
Charge the battery packs at temperatures between 0
°
C and 40
°
C (32
°
F and 104
°
F).
To charge the battery pack
1. If you have a Sabre charge strip (Part No. 067255 or Part No. 067254), see the
Sabre Charge Strip Instructions (Part No. 067674) for how to load and unload the
battery pack in the charge strip.
If you do not have a charge strip and if you use the battery pack in North America,
insert the battery pack into a wall socket.
2. When the battery pack light turns from red to green, remove the battery pack from
the charge strip or wall socket and install the battery pack into your scanner.
Note: The battery pack will charge at a slower rate after the light changes from red to
green.
Installing the Battery Pack
1. Push in the battery pack clips.
2. Insert the battery pack into the base of the scanner.