Citel 3000 Betriebsanweisung

Seite von 120
EXTender 3000 System Administrator’s Guide (Definity)
Ethernet Data Type Configuration
Page 79
Alternatively, on the remote side, it is possible to directly connect a PC’s Ethernet LAN card directly to the 
Ethernet port on the EXTender. In this case, you must use an Ethernet crossover cable (with the pin-outs 
shown in the table below.
Configuration Parameters
If you are using Ethernet Data, you may need to configure the following types of parameters:
Data Phone Number
Point-To-Point Protocol (PPP)
Bridging
DN1/MSN1 and DN2/MSN2.
The following Remote Module Ethernet parameters are optional:
Point-To-Point Protocol – Data-on-demand
Note: you must also program DN/MSN1 and DN2/MSN2 in the ISDN menu for the Ethernet to work cor-
rectly.
For detailed instructions for setting these parameters, see the Ethernet menu options in the sections Setting 
ISDN Parameters and Configuration using a Digital Telephone.
Table 12: RJ-45 to RJ-45 crossover Ethernet cable pin-out
RJ-45 Pin
Signal
Direction
RJ-45 Pin
Signal
1
Tx+
->
3
Rx+
2
Tx-
->
6
Rx-
3
Rx+
<-
1
Tx+
4
-
-
4
-
5
-
-
5
-
6
Rx-
<-
2
Tx-
7
-
-
7
-
8
-
-
8
-