RUNNING THE DIAGNOSTICS
 
Click on Looptest to run the tests in a repeated loop.
The loop option menu appears. Click on a device;
the 
 mark appears beside the selected device.
Repeat this step to select multiple devices. Click on
OK to start the diagnostic loop. If no device is
selected, all devices tests are looped.
9. To exit the loop, keep pressing Ctrl
+
Pause until the
test exits. A beep sounds to notify that the exit
interrupt is sensed by the test program. Press Esc to
exit from the loop test.
PC Card Slots Test
The green LED on the PC test card turns on when the PC
Card slot test is running. If the LED does not turn on,
check that the card is installed correctly by reseating it. If
the LED still does not turn on after the card is reseated, try
using another slot for the test. If the LED still does not
turn on and the test fails, replace the FRU shown by the
diagnostic error code.
Universal Serial Bus (USB) Test
At the advanced diagnostic window, do the following:
1. Connect the USB parallel test cable to the parallel
connector of the computer.
2. Connect Connector 1 of the cable to the USB
connector of the computer.
  Note 
The illustration shows a ThinkPad 770 computer,
but the procedure is the same for the other
model.
   