Calflame bbq07877p Benutzeranleitung

Seite von 16
Installation / Assembly
2007 Pizza Oven Owner’s Manual 
Page 5
LTR20071039, Rev. A
LP Gas Hook Up
Vent the enclosure for an LP gas cylindar with openings 
at the level of the cylinder valve and at the floor level. 
Ensure one side of the enclosure is completely open.
For enclosures that have four sides, complete with a 
top and bottom:
At least two ventilation openings at cylinder valve         
less than one square inch per pound (7.1 cm²/kg) 
of stored fuel capacity and not less than a total free 
area of 10 square inches (64.5cm²). If ventilation 
openings at floor level are in a sidewall, there 
shall be at least two openings. The bottom of the 
openings shall be at floor level and the upper edge 
no more than 5 inches (127 mm) above the floor. 
The openings shall be equally sized, spaced at 
180º (3.14 rad) and unobstructed.
Every opening shall have minimum dimensions so 
as to permit the entrance of a 1/8 inch (3.2 mm) 
diameter rod.
Transporting and Storing LP Gas
Place the dust cap on the cylinder valve outlet 
whenever the cylinder is not in use. Only install the type 
of dust cap on the cylinder valve outlet that is provided 
with the cylinder valve. Other types of caps or plugs 
may result in leakage of propane.
Transport only one cylinder at a time. Ensure the 
cylinder is secured in an upright position with the 
control valve turned off and the dust cap in place. Store 
cylinders outdoors and out of reach of children. Do 
not store cylinders in a building, garage, or any other 
enclosed area.
Warning: All pizza ovens use LP unless they are 
converted to natural gas. Do not connect natural gas to 
an unconverted pizza oven!
Requirements
Always check the rating plate to make sure the gas 
supply you are hooking up to is the gas type the pizza 
oven is manufactured for.
IMPORTANT: Never connect the pizza oven to an 
unregulated gas supply.
The installation of this appliance must conform with 
local codes or, in the absence of local codes, to the 
national fuel gas code, ANSI Z223.1a-1998. Installation 
in Canada must be in accordance with the standard 
CAN/CGA-B149.2, Propane Installation Code.
A licensed contractor or local gas company 
representative must perform all natural gas 
connections.
Ensure that the service supplying the pizza oven is 
fitted with a shut off valve conveniently positioned near 
the pizza oven and giving ease of access.
The pizza oven and its individual shutoff valve must be 
disconnected from the gas supply piping system during 
any pressure testing of that system at test pressure in 
excess of 0.5 psi (3.5 kPa).
Your pizza oven for use with natural gas comes 
equipped with its own regulator that MUST NOT 
be removed. If this regulator needs to be replaced, 
use only the type specified by Cal Flame™ for this 
appliance.
Connection
Remove the rear panel from the pizza oven to gain 
access to the regulator and gas connection point.
Connect a suitable flex connector to the regulator.
Check the controls to ensure all control valves are 
in the full OFF position.
Turn on the main gas supply and check all 
connections for leaks using soapy water as 
described in the leak testing procedure section.
Warning: If you see bubbles in the soapy solution at 
any of the connections, turn off the gas supply and 
tighten the connection. If tightening the connection 
does not seal the leak, it may be necessary to replace 
the flex hose.
1.
2.
3.
4.
Natural Gas