Blomberg dv 16540 Betriebsanweisung

Seite von 24
11 - EN
when they are full.  Therefore, the floor 
must be capable of carrying the load 
placed on it!
Adjusting the feet
In order to ensure that your 
appliance operates more 
silently and vibration-free, 
it must stand level and 
balanced on its feet.  The 
front feet of the appliance 
can be adjusted. Balance 
the appliance by adjusting the feet.
1.   Loosen the feet by hand.
2.   Adjust them until the appliance stands 
level and firmly.
C
  Do not use any tools to loosen the 
adjustable feet. Otherwise, they may be 
damaged.
C
  Never unscrew the adjustable feet from 
their housings.
2 plastic pieces supplied together with the 
Operating Instructions prevent your 
appliance from slipping on wet and 
slippery surfaces. To install these plastic 
parts:
1.   Tilt the appliance backwards.
2.   Fit the plastic parts to the front adjustable 
feet. Press on the plastic parts to fix them 
in their places.
3.   Check the balance of the appliance 
again and readjust the adjustable feet if 
necessary.
Ventilation duct and 
connection 
Ventilation duct ensures exhaust of air from 
inside the appliance.
The vented dryer has 1 air outlet.
A
  Only rigid or flexible metal duct should 
be used for exhausting, unless the 
appliance has been checked for use with 
nonmetallic duct or the duct has been 
checked and found acceptable for use 
with clothes dryers. 
The diameter of the duct to be used should be 
4” (102 mm).
Maximum duct length is given in the table 
below:
Metal rigid duct
Maximum length
21 ft (6.5 m) + 2 elbows
To connect a ventilation duct;
1.  Connect the air outlet metal duct to the 
spacer by turning it counter-clockwise.
Make the duct passages as shown the 
2. 
picture below.
C
  Exhaust of humid air from the dryer into 
the room is to be avoided. It may damage 
the walls and furniture in the room.
C
  The ventilation duct can be routed 
outdoors via a window or it can be 
connected to the air outlet in a
 bathroom.
C
  Air outlet duct must be extended directly 
outdoors. There must be a limited number 
of elbows to not hinder air flow.
C
  To prevent water accumulation in the 
duct, make sure it is not folded on the 
floor.
A
  The appliance should not be vented into a 
chimney, a wall, a ceiling, or a concealed 
space of a building. 
A
  Do not operate the appliance at the same 
time with heaters such as a coal or gas 
stove. Airflow may cause the chimney to 
flare up. 
C
   Care must be taken not to pinch or bend 
the ducts. 
C
   The end of the hose should not be bent, 
it should not be stepped on and it must 
not be folded between the drain and the 
machine.
C
   The duct shall not be assembled with 
screws or other fastening means that 
extend inside the duct to catch lint.