Panasonic aj-sdx900 Benutzerhandbuch
90
Chapter 7 Menu description tables
7-5-6
WHITE BALANCE MODE
AWB B
MEM
ATW
VAR
ATW
VAR
For selecting the allocation of the WHITE BAL
switch position and Bch.
MEM: The switch position and Bch are
switch position and Bch.
MEM: The switch position and Bch are
allocated as memory values when
AWB is executed.
AWB is executed.
ATW: The position and Bch are allocated as
ATW start switch functions.
VAR: The color temperature of B can be set
to vary using the COLOR TEMP B
menu item.
menu item.
COLOR TEMP B
3200K
:
5600K
For setting the color temperature when AWB
B has been set to VAR.
B has been set to VAR.
Item
Variable
range
Remarks
FILTER INH
ON
OFF
OFF
For selecting whether or not to keep the AWB
memory (Ach, Bch) data for each filter.
ON:
memory (Ach, Bch) data for each filter.
ON:
The data is kept in the two Ach and Bch
memories for each filter used.
memories for each filter used.
OFF: The data is kept for each filter.
SHOCKLESS AWB
OFF
FAST
NORMAL
SLOW1
SLOW2
SLOW3
FAST
NORMAL
SLOW1
SLOW2
SLOW3
For selecting ON (FAST/NORMAL/SLOW1-3)
or OFF for SHOCKLESS AWB which ensures
that the setting of the white balance switch to
PRST, A or B is not accompanied by a shock.
In addition, the switching time can be
selected.
or OFF for SHOCKLESS AWB which ensures
that the setting of the white balance switch to
PRST, A or B is not accompanied by a shock.
In addition, the switching time can be
selected.
AWB AREA
25%
50%
90%
50%
90%
For selecting the AWB detection area.
25%: An area near the screen center
25%: An area near the screen center
equivalent to 25% of the screen is
detected.
detected.
50%: An area near the screen center
equivalent to 50% of the screen is
detected.
detected.
90%: An area equivalent to 90% of the
screen is detected.
AWB & ABB
OFFSET
OFFSET
ON
OFF
OFF
For selecting whether or not to reset the GAIN
and PED values on the ROP menu when
AWB or ABB is executed.
ON:
and PED values on the ROP menu when
AWB or ABB is executed.
ON:
The values are not reset.
OFF: The values are reset.
COLOR TEMP PRE
3200K
:
5600K
For selecting the AWB PRE color
temperature.
temperature.
AWB A
MEM
VAR
VAR
For selecting the allocation of the WHITE BAL
switch position and Ach.
MEM: The switch position and Ach are
switch position and Ach.
MEM: The switch position and Ach are
allocated as memory values when
AWB is executed.
AWB is executed.
VAR: The color temperature of A can be set
to vary using the COLOR TEMP A
menu item.
menu item.
COLOR TEMP A
3200K
:
5600K
For setting the color temperature when AWB
A has been set to VAR.
A has been set to VAR.
ATW SPEED
NORMAL
SLOW
FAST
SLOW
FAST
For selecting the ATW control speed.
7-5-7
USER SW GAIN
Item
Variable
range
Remarks
S.GAIN
30 dB
¢
•
For selecting whether or not to enable a
setting of 30 dB for SUPER GAIN.
setting of 30 dB for SUPER GAIN.
¢
: The 30 dB setting is enabled.
•: The 30 dB setting is disabled.
36 dB
¢
•
For selecting whether or not to enable a
setting of 36 dB for SUPER GAIN.
setting of 36 dB for SUPER GAIN.
¢
: The 36 dB setting is enabled.
•: The 36 dB setting is disabled.
42 dB
¢
•
For selecting whether or not to enable a
setting of 42 dB for SUPER GAIN.
setting of 42 dB for SUPER GAIN.
¢
: The 42 dB setting is enabled.
•: The 42 dB setting is disabled.
48 dB
¢
•
For selecting whether or not to enable a
setting of 48 dB for SUPER GAIN.
setting of 48 dB for SUPER GAIN.
¢
: The 48 dB setting is enabled.
•: The 48 dB setting is disabled.
DS.GAIN
6 dB
:
¢
•
For selecting whether or not to enable a
setting increase of 6 dB for DS.GAIN.
setting increase of 6 dB for DS.GAIN.
¢
: The 6 dB setting increase is enabled.
•: The 6 dB setting increase is disabled.
12 dB
:
¢
•
For selecting whether or not to enable a
setting increase of 12 dB for DS.GAIN.
setting increase of 12 dB for DS.GAIN.
¢
: The 12 dB setting increase is enabled.
•: The 12 dB setting increase is disabled.
20 dB
:
¢
•
For selecting whether or not to enable a
setting increase of 20 dB for DS.GAIN.
setting increase of 20 dB for DS.GAIN.
¢
: The 20 dB setting increase is enabled.
•: The 20 dB setting increase is disabled.
The underlining in the variable range column indicates the setting in the preset mode.