8-6-2 BATTERY SETTING1
The ____ in the Adjustable Range column indicates the
preset mode. 
Items/
Data Saved 
Adjustable 
Range 
Remarks 
CARD NEAR 
END ALARM
ON
OFF
Select whether or not to set the alarm 
to beep for P2 CARD NEAR END 
ALARM. 
– C U F –
CARD NEAR 
END TIME 
2min
3min
Set the remaining time to indicate the 
P2 CARD NEAR END TIME alarm. 
– C U F –
CARD END 
ALARM
ON
OFF
Select whether or not to set the alarm 
to beep for P2 CARD END ALARM. 
– C U F –
CARD REMAIN/
„
3min/
„
5min/
„
Set the length of time for one segment 
(
„) of the P2 card’s remaining capacity 
indicator bars. 
3min/
„One segment represents 3 
minutes. 
5min/
„One segment represents 5 
minutes. 
– C U F –
Items/
Data Saved 
Adjustable 
Range 
Remarks
PRO14
_
Enable selection under BATTERY 
SELECT. 
_:Enable selection. 
 • :Disable selection.
MANUAL
AUTO
Select auto or manual to set the NEAR 
END voltage. 
MANUAL: Set voltage manually. 
AUTO: Set voltage automatically. 
11.0
 : 
13.9
 : 
15.0
When MANUAL is selected in the 
above menu, set the NEAR END 
voltage in 0.1 V steps. 
– C U F –
TRIM14
_
Enable selection under BATTERY 
SELECT. 
_:Enable selection. 
 • :Disable selection.
MANUAL
AUTO
Select auto or manual to set the NEAR 
END voltage. 
MANUAL: Set voltage manually. 
AUTO: Set voltage automatically. 
11.0
 : 
13.6
 : 
15.0
When MANUAL is selected in the menu 
above, set the NEAR END voltage in 
0.1 V steps. 
– C U F –
HYTRON50
_
Enable selection under BATTERY 
SELECT. 
_:Enable selection. 
 • :Disable selection.
MANUAL
AUTO
Select auto or manual to set the NEAR 
END voltage. 
MANUAL: Set voltage manually. 
AUTO: Set voltage automatically. 
11.0
 : 
13.1
 : 
15.0
When MANUAL is selected in the menu 
above, set the NEAR END voltage in 
0.1 V steps. 
– C U F –
HYTRON100
_
Enable selection under BATTERY 
SELECT. 
_:Enable selection. 
 • :Disable selection.
MANUAL
AUTO
Select auto or manual to set the NEAR 
END voltage. 
MANUAL: Set voltage manually. 
AUTO: Set voltage automatically. 
11.0
 : 
13.2
 : 
15.0
When MANUAL is selected in the menu 
above, set the NEAR END voltage in 
0.1 V steps. 
– C U F –
HYTRON120
_
Enable selection under BATTERY 
SELECT. 
_:Enable selection. 
 • :Disable selection.
MANUAL
AUTO
Select auto or manual to set the NEAR 
END voltage. 
MANUAL: Set voltage manually. 
AUTO: Set voltage automatically. 
11.0
 : 
13.1
 : 
15.0
When MANUAL is selected in the menu 
above, set the NEAR END voltage in 
0.1 V steps. 
– C U F –
#,52%2 'PINKUJDQQMࡍ࡯ࠫ㧞㧜㧜㧢ᐕ㧡᦬㧝㧝ᣣޓᧁᦐᣣޓඦ೨㧥ᤨ㧠㧡ಽ