7
Chapter 7 Maintenance and Inspections 
(continued)
6. Inspection of the clock, time code, and user bits
1
Set the user’s bit as required. 
Please refer to [4-5-1 Setting the User Bits] for the
setting procedures. 
2
Set the time code. 
Please refer to [4-5-3 Setting the Time Code] for the
setting procedures. 
3
Set the TCG switch to [R-RUN]. 
4
Press the REC START/STOP button. 
Check that the counter display number changes as
recording progresses. 
5
Press the REC START/STOP button again. 
Check that recording stops and the counter display
number stops changing. 
6
Set the TCG switch to [F-RUN]. 
Check that the counter display number changes
regardless of recording status. 
7
Set the DISPLAY switch to [UB]. 
Each time the HOLD button is pressed, make sure that
the displayed value changes in the following sequence:
VTCG 
 DATE  TIME  No display (time zone) 
TCG; and also verify that the displayed value is correct. 
If DATE, TIME, or time zone is not correct, refer to [4-5-
2 Setting the Internal Clock’s Date and Time
] for
guidance on setting the correct values.
<Note>
Note that date and time data set for DATE, TIME, and
time zone is recorded in clips, and affects the playback
sequence, etc. at the time of thumbnail manipulations.
7-2 Maintenance
7-2-1 Cleaning Inside the Viewfinder
z Do not use thinner or other solvents to remove dirt from
the viewfinder. 
z Wipe the lens with a commercially available lens cleaner. 
z Do not wipe the mirror. If dirt or rubbish is sticking on the
mirror, remove it with a commercially available air blower. 
7-2-2 Phenomenon Inherent to CCD 
Cameras
Smears
Smears may appear when shooting an object with very high
brightness. 
This phenomenon may appear more frequently as the
electronic shutter speed increases. 
7-2-3 Replacing the Backup Battery
The camera is shipped from the factory with a backup
battery already mounted. 
When the battery runs out, the [BACK UP BATT EMPTY]
display appears on the viewfinder screen for 5 seconds after
the power switch is turned ON. 
The internal clock stops operating when the battery runs out.
Also, the TCG time code value returns to [00:00:00:00], and
the time code backup is disabled. The battery must be
replaced. 
Please consult your distributor for replacement with a new
battery (CR2032). 
The backup battery is visible when the panel on the LCD
monitor side is removed (right side when viewed from the
front). 
<Note>
Please contact the store where you purchased the camera
when replacing the battery. 