Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
3. Use 
³⁄₈" nut driver to connect the bare (green) ground wire to 
the center terminal block post with one of the 10-32 hex nuts.
4. Connect line 1 (black) and line 2 (red) wires to the outer 
terminal block posts with 10-32 hex nuts.
5. Securely tighten hex nuts.
6. Replace terminal block access cover.
Verify Anti-Tip Bracket Location
1. Make sure the anti-tip bracket is installed:
Look for the anti-tip bracket securely attached to floor or 
wall.
Slide range back so rear range foot is under the anti-tip 
bracket.
Level Range
1. Place oven rack in oven. 
2. Place level on oven rack and check levelness of range, first 
side to side; then front to back.
3. If range is not level, pull range forward until rear leveling leg is 
removed from the anti-tip bracket.
4. Use wrench to adjust leveling legs up or down until range is 
level. Push range back into position.
5. Check that rear leveling leg is engaged in anti-tip bracket.
NOTE: Range must be level for satisfactory baking performance.
Complete Installation
1. Check that all parts are now installed. If there is an extra part, 
go back through the steps to see which step was skipped.
2. Check that you have all of your tools.
3. Dispose of/recycle all packaging materials.
4. Check that the range is level. See “Level Range.”
5. Use a mild solution of liquid household cleaner and warm 
water to remove waxy residue caused by shipping material. 
Dry thoroughly with a soft cloth. For more information, read 
the “Range Care” section of the Use and Care Guide.
6. Read the range Use and Care Guide.
7. Plug power cord into appropriate outlet. Slide range into its 
final location. Check that the flexible conduit or power supply 
cord are not bent.
8. Turn power on. Turn on surface elements and oven. See the 
Use and Care Guide for specific instruction on range 
operation. 
If range does not operate, check the following:
Household fuse is intact and tight; or circuit breaker has not 
tripped.
Range is plugged into an outlet.
Electrical supply is connected.
See “Troubleshooting” in the Use and Care Guide.
When the range has been on for 5 minutes, check for heat. If 
range is cold, turn off the range and contact a qualified 
technician.
Wire Awg
Torque
8 gauge copper
25 lbs-in. (2.8 N-m)
6 gauge aluminum
35 lbs-in. (4.0 N-m)
A. 10-32 hex nut
B. Line 1 (black)
C. Ground-link screw
D. Bare (green) ground wire
E. Line 2 (red)
F. Terminal lug
B
F
A
E
D
C