The fourth (grounding) conductor must be identified by a green or 
green/yellow cover and the neutral conductor by a white cover. 
Cord should be Type SRD or SRDT with a UL listed strain relief 
and be at least 4 ft (1.22 m) long.
The minimum conductor sized for the copper 4-wire power 
cord are:
40-amp circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No.-8 green grounding
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire, 250-volt, 
40- or 50-amp range power supply cord (pigtail). This cord 
contains 3 copper conductors with ring terminals or open-end 
spade terminals with upturned ends, terminating in a NEMA Type 
10-50P plug on the supply end. Connectors on the appliance end 
must be provided at the point the power supply cord enters the 
appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
Electrical Requirements - Canada Only
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path is adequate and wire gauge are in accordance 
with local codes.
Be sure that the electrical connection and wire size are adequate 
and in conformance with CSA Standard C22.1, Canadian 
Electrical Code, Part 1 - latest edition, and all local codes and 
ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA.
Check with a qualified electrical installer if you are not sure 
the range is properly grounded.
*The NEC calculated load is less than the total connected load 
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with 
kit. For 50-amp rated cord kits, use kits that specify use with a 
nominal 1
³⁄₈" (34.9 mm) diameter connection opening.
A time-delay fuse or circuit breaker is recommended.
This range is equipped with a CSA International Certified 
Power Cord intended to be plugged into a standard 14-50R 
wall receptacle. Be sure the wall receptacle is within reach of 
range’s final location.
Do not use an extension cord.
Countertop Preparation
(for Slide-in Ranges Only)
The cooktop sides of the slide-in range fit over the cutout edge of 
your countertop.
If you have a square finish (flat) countertop and the opening width 
is 30" (76.2 cm), no countertop preparation is required.
Formed front-edged countertops must have molded edge 
shaved flat 
³⁄₈" (1.0 cm) from each front corner of opening.
Tile countertops may need trim cut back 
³⁄₈" (1.0 cm) from each 
front corner and/or rounded edge flattened. 
If countertop opening width is greater than 30" (76.2 cm), adjust 
the 
³⁄₈" (1.0 cm) dimension.
Countertop must be level. Place level on countertop, first side to 
side, then front to back. If countertop is not level, range will not 
be level. Range must be level for satisfactory baking conditions.
4-wire receptacle (14-50R)
3-wire receptacle (10-50R)
WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or 
electrical shock.
Range Rating*
Specified Rating of 
Power Supply Cord Kit 
and Circuit Protection
120/240 Volts
120/208 Volts
Amps
8.8 - 16.5 KW
16.6 - 22.5 KW
7.8 - 12.5 KW
12.6 - 18.5 KW
40 or 50**
50
30"
(76.2 cm)
30 ¾"
(78.1 cm)
³⁄₈
"
(1.0 cm)