3com 4800G Installationsanweisungen
Verifying the Installation
51
Removing the Dedicated
CX4 Cable
1 Wear an ESD-preventive wrist strap and verify the ESD-preventive wrist strap is
properly grounded.
2 Hold the CX4 cable connector, pull the handle at the end of the connector to
horizontally unplug the CX4 cable connector from the CX4 port.
c
CAUTION:
■
Dedicated CX4 cables of the Switch 4800G are hot pluggable.
■
Make sure that the cable bending radius is no less than eight times the cable
diameter when connecting the CX4 cable.
diameter when connecting the CX4 cable.
Verifying the
Installation
Installation
Check the following:
■
The selected power supply complies with the one labeled on the switch.
■
The grounding cable is connected.
■
The console cable and power cable are connected correctly.
■
All the interface cables are routed indoors. If there are cables outdoors, the
socket strip with lightning protection and lightning arresters for network ports
have been correctly connected.
socket strip with lightning protection and lightning arresters for network ports
have been correctly connected.