3com S7906E Installationsanweisungen

Seite von 2621
 
1-6 
Table 1-1 Restrictions on the configuration of RMON 
Entry 
Parameters to be compared 
Maximum number of 
entries that can be 
created 
Event 
Event description (description string), event type (log, 
trap
logtrap or none) and community name 
(trap-community or log-trapcommunity
60 
Alarm 
Alarm variable (alarm-variable), sampling interval 
(sampling-interval), sampling type (absolute or delta), 
rising threshold (threshold-value1) and falling threshold 
(threshold-value2
60 
Prialarm 
Alarm variable formula (alarm-variable), sampling 
interval (sampling-interval), sampling type (absolute, 
changeratio
 or delta), rising threshold 
(threshold-value1) and falling threshold 
(threshold-value2
50 
 
Displaying and Maintaining RMON 
To do… 
Use the command… 
Remarks 
Display RMON statistics 
display rmon statistics 
interface-type 
interface-number 
Available in any view 
Display the RMON history 
control entry and history 
sampling information 
display rmon history 
interface-type 
interface-number
 ] 
Available in any view 
Display RMON alarm 
configuration information 
display rmon alarm 
entry-number ] 
Available in any view 
Display RMON prialarm 
configuration information 
display rmon prialarm 
[ entry-number ] 
Available in any view 
Display RMON events 
configuration information 
display rmon event 
[ entry-number ] 
Available in any view 
Display log information for the 
specified or all event entries. 
display rmon eventlog 
entry-number ] 
Available in any view 
 
Ethernet Statistics Group Configuration Example 
Network requirements 
As shown in 
, Agent is connected to a configuration terminal through its console port and to 
Server through Ethernet cables. 
Gather performances statistics on received packets on GigabitEthernet 2/0/1 through RMON Ethernet 
statistics table, and thus the administrator can view the statistics on packets received on the interface at 
any time.