3com S7906E Verweisanleitung

Seite von 2327
 
1-17 
undo lldp check-change-interval 
View 
Ethernet interface view, port group view 
Default level 
2: System level 
Parameters 
value: LLDP polling interval to be set, in the range 1 to 30 (in seconds). 
Description 
Use the lldp check-change-interval command to enable LLDP polling and set the polling interval. 
Use the undo lldp check-change-interval command to restore the default. 
By default, LLDP polling is disabled. 
With LLDP polling enabled, LLDP detects for local configuration changes periodically. A local 
configuration change triggers LLDPDU sending, through which neighboring devices can be informed of 
the configuration change timely. 
Examples 
# Enable LLDP polling on GigabitEthernet2/0/3, setting the polling interval to 30 seconds. 
<Sysname> system-view 
[Sysname] interface gigabitethernet2/0/3 
[Sysname-GigabitEthernet2/0/3] lldp check-change-interval 30 
lldp compliance admin-status cdp 
Syntax 
lldp compliance admin-status cdp { disable txrx } 
View 
Ethernet interface view, port group view 
Default Level 
2: System level 
Parameters 
disable: Specifies the disable mode, where CDP-compatible LLDP neither receives nor transmits CDP 
packets.  
txrx: Specifies the TxRx mode, where CDP-compatible LLDP can send and receive CDP packets.  
Description 
Use the lldp compliance admin-status cdp command to configure the operation mode of 
CDP-compatible LLDP on a port or port group.  
By default, CDP-compatible LLDP operates in disable mode.