8. 
Decide which RAID setting 
you want, and, following 
the diagram to the right, 
move the jumper shunts to 
cover the appropriate pins. 
(On the diagram to the 
right, grey indicates that a 
pin is covered; white 
indicates an uncovered pin.) 
 
The jumper shunts may be 
moved by gently pulling 
them upwards (vertically) 
until they are free, then 
pushing them downwards 
onto the appropriate two 
pins. 
 
NOTE: If switching from any mode to RAID 1 mode, you must first configure 
the jumper block to “Single” mode. Then connect your drive to your 
computer, turn on your drive, and repeat step 5 (un-initialization) on BOTH 
drives (in single mode, the array will show up as two drives). Then you may 
continue again from Step 6 and configure the jumper block to RAID 1.   
 
NOTE: When placing the jumper shunts, make sure they are oriented 
along the longest axis of the drive.
 For example, if you want RAID 1 
mode, one jumper shunt would cover pins 1 and 2, and another jumper shunt 
would cover pins 4 and 5, as opposed to one jumper shunt covering pins 1 
and 4, and another jumper shunt covering pins 2 and 5.  
 
Fig. A (below) shows how the [uncovered] jumper pins are numbered. The 
black arrow points to the back of the drive.  
 
 
 
Fig. A 
 
 
 
14