Gestetner c7528 Bedienungsanleitung

Seite von 341
Monitoring and Configuring the Printer
217
Remote Maintenance by telnet
❒ Remote Maintenance should be password-protected so that access is al-
lowed to administrators only.
❒ The password is the same as the one of Web Image Monitor administrator.
When the password is changed using “mshell”, other passwords change also.
❒ Some commands cannot be used depending on your printer.
Using telnet
Follow the procedure below to use telnet.
❒ Only one user at a time can log on to perform remote maintenance.
A
Use the IP address or the host name of the printer to start telnet.
% telnetIP_address
B
Enter your user name and password.
To use default account, enter “admin” as user name, and leave the password
blank.
C
Enter a command.
D
Quit telnet.
msh> logout
The configuration message about saving the changes appears.
E
Enter “yes” to save the changes, and then press the {# Enter} key.
If you do not want to save the changes, enter “no”, and then press the {# En-
ter
} key. To make further changes, enter “return” at the command line, and
then press the {# Enter} key.
❒ If the message “Can not write NVRAM information” appears, the changes
are not saved. Repeat the procedure above.
❒ When the changes are saved, the network interface board is reset auto-
matically with that changes.
❒ When the network interface board resets, the print job in print process will
be printed. However, print jobs in queue will be canceled.