Gestetner cs331 Servicehandbuch
5-19
1
2
3
4
5
6
7
9
10
11
12
8
4
When centering a part of an original, place the
original on the glass to specify the area.
- Set the original face up with the bottom toward you, fit its
top left corner against the top left corner of the glass, and
align it with the original scale.
align it with the original scale.
5
Using the original scale on the left and the inner
(top) scale, read the position of the desired area, as
follows:
- X1 Distance from the top left to the left edge of the specified
area.
- X2 Distance from the top left to the right edge of the specified
area.
- Y1 Distance from the top left to the upper edge of the
specified area.
- Y2 Distance from the top left to the lower edge of the
specified area.
6
Enter the distance values read in step 5 for the
specified area.
- Key in the value for X1 with the digital keys and press the
upper SET key.
- Similarly, set the values for X2, Y1 and Y2.
7
Press the lower SET key.
8
Place the original(s) on the glass face down and
with its bottom toward you and with its top left
aligned against the original scale on the left side.
Page 2-9
Select other copy modes as required.
9
Press the START key.