Safety Rules
1.  Read instructions carefully.
2.  Electrical hook up should be done by a qualifi ed electrician, so 
that all electrical wiring will conform to your local standards.
3.  Unit must be in the OFF POSITION and UNPLUGGED from 
power receptacle when installing or performing any mainte-
nance.
4.  Your cooler will run on 120 volt AC., 60 Hz (cycle) current 
only.
5.  Motor and pump are grounded and have an automatic thermal 
overload switch which will shut motor off when it overheats.  The 
motor will restart automatically when it cools down.
WARNING
:  To reduce the risk of fi re or electric shock, do not 
use this fan with any “solid-state fan speed control device.”
Read And Save These Instructions
Evaporative Cooling
With this unit being a fresh air system, you are not trapped with 
recirculating air that can become stale, laden with smoke and odors, 
as happens with refrigerated air conditioning systems.  Instead, 
you are completely replacing the air every 2 to 4 minutes by either 
opening doors or windows or a combination of both to exhaust the 
air continually.
How much should you open your windows?   To obtain the maximum 
cooling capacity of your cooler, you should open your windows until 
the air inside the house is nearly balanced with the air outside.  As 
you open your windows you decrease the pressure buildup inside the 
home, and the cooler is able to output increasingly more air until the 
capacity of the cooler is reached.
One method to determine when the air is reasonably balanced is to 
place a piece of tissue paper up against the screen of the window 
furthest from the cooler and adjust the opening of the windows in the 
house until the tissue paper stays lightly on the screen.  If the tissue 
plasters itself to the screen, open the windows more.  If it falls, close 
the windows more.
Vea el español en el interior.
110499
8-08
Operation
To eliminate delivery of hot air when starting cooler, turn on pump 
only for the fi rst few minutes, then turn on the blower motor.
These coolers may be used without water for ventilation purposes.  
When outside air is cool (for example, at night) or when humidity is 
high the water pump can be turned off.