Lab.gruppen fp 10000q Техническое Руководство

Seite von 1
Item no. CDTD_FP13000_V4
Current Draw and Thermal Dissipation
FP+ Series: Dedicated Touring Amplifiers
FP 13000
L a b . g r u p p e n   a b   •   S w e d e n
  i n t e r n a t i o n a L   c o n t a c t   •   i n f o @ L a b g r u p p e n . c o m       |       u S   c o n t a c t   •   i n f o @ t c u S . c o m
w w w . l a b g r u p p e n . c o m
-10dB
-inf
0
-10dB
-inf
0
B
channel
channel
A
FP SERIES
VHF
TEM
VHF
TEM
channel A
  -20   -15   -10 -4 VPL CPL
channel B
  -20   -15   -10 -4 VPL CPL
BRIDGE A+B
SIG
SIG
PWR
PAL
NOMAD
    LINK
MUTE
MUTE
 
CLIP
 
CLIP
 
HI-IMP
 
HI-IMP
FP13000
R
POW
POW
The following tables contain information on measured current consumption as well as calculated heat dissipation during normal operation 
(1/8 rated power); and during extreme heavy duty operation (1/4 rated power).
FP 13000
Level
Load
Rated Power
Line Current *2)
Watt *1)
Thermal Dissipation
115 VAC
230 VAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby, with remote power off via NomadLink
0
0
0
0
0
Powered on, idling
129
0
129
440
111
Amp (I)
Watt
Pink noise (1/8 
rated power)
16 
Ω / Ch.
1200 x 2
10.6
5.3
678
300
378
1289
325
32 
Ω / Bridged
2400 x 1
Ω / Ch.
2350 x 2
16.2
8.1
1083
588
495
1690
426
16 
Ω / Bridged
4700 x 1
Ω / Ch.
4400 x 2
26.5
13.2
1856
1100
756
2578
650
Ω / Bridged
8800 x 1
Ω / Ch.
6500 x 2
37.8
18.9
2536
1625
911
3109
783
Ω / Bridged
13000 x 1
Pink noise (1/4 
rated power) 
*3)
16 
Ω / Ch.
1200 x 2
16.0
8.0
1037
800
237
807
203
32 
Ω / Bridged
2400 x 1
Ω / Ch.
2350 x 2
27.2
13.6
1840
1567
273
933
235
16 
Ω / Bridged
4700 x 1
Ω / Ch.
4400 x 2
48.3
24.1
3419
2933
486
1659
418
Ω / Bridged
8800 x 1
Ω / Ch.
6500 x 2
58.0
29.0
4243
3250
993
3390
854
Ω / Bridged
13000 x 1
Mains connector, 230 V CE version
16 A, CEE7
Mains connector, 115 V ETL version
30 A, Nema L5-30P Twist lock
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and 
specified here is what is known as the “Active Power” of the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum power before amplifier protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated 
power. Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be 
tripped even if operation is in excess of max. ratings.