Heartland 3015 Betriebsanweisung

Seite von 40
24
Use & Care Guide
System Specification and Performance Data Sheet
Refrigerator Water Filter Cartridge Model
Average M axim um  Average  M inim um  
Chlorine —  
2.0 
m g/L ± 10% 
1.88 m g / L 
<0.05136364 m g /L 
0.06 m g /L 
>97.26%  
96.84%
50%
T  &  O 
—  
—  
—  
—  
—  
—  
—  
—  
Particulate** 
—  
at least 10,000 particles / m l 
5,700,000 # /m l 
30,583 # /m l 
69,000 #/m l 
99.52%
98.94%
85%
Average M axim um  Average  M inim um  
Turbidity 
1 NTU** 
11 ± 1 NTU*** 
10.7 NTU 
0.31 NTU 
.049 NTU 
97.09%
95.20%
0.5 NTU 
Cysts 
99.5%  Reduction 
M inim um  50,000/L 
166,500 #/L 
<1 #/L 
<1 #/L 
>99.99%  
>99.99%  
>99.95%  
Asbestos 99%  
Reduction 
107 108 fibers/L; fibers >10 m icrom eters in length 
155 M F/L 
<1 M F/L 
<1 M F/L 
>99.99%  
>99.99%  
99%
Lead at pH 6.5 
0.015 m g/L 
0.15 m g/L + 10%  
0.153 m g/L 
< .001 m g/L 
< .001 m g/L >99.35%   >99.29%   0.10 
m g/L 
Lead at pH 8.5 
0.015 m g/L 
0.15 m g/L + 10%  
0.150 m g/L 
< .001 m g/L 
< .001 m g/L >99.33%   >99.29%   0.10 
m g/L 
M ercury at pH 6.5 
0.002 m g/L .006 
m g/L ± 10% 
0.006 m g/L 0.0003 
m g/L 0.0005 
m g/L 95.70%
90.91%
0.002 
m g/L 
M ercury at pH 8.5 
0.002 m g/L .006 
m g/L ± 10% 
0.006 m g/L 0.0008 
m g/L 0.0015 
m g/L 86.22%
75.93%
0.002 
m g/L 
Atrazine 0.003 
m g/L 0.009 
m g/L + 10%  
0.009 m g/L 
< 0.002 m g/L 0.002 
m g/L 76.99%
75.31%
0.003 
m g/L 
Lindane 0.0002 
m g/L 0.002 
m g/L + 10%  
0.002 m g/L 0.000 
m g/L 
< 0.0001 m g/L 98.72%
96.50%
0.0002 
m g/L 
Toxaphene 0.003 
m g/L 
0.015 ± 10%  
0.015 m g/L <0.001 
m g/L <0.001 
m g/L 92.97%
91.67%
0.003 
m g/L 
Standard No. 42: Aesthetic Effects 
Influent Challenge Concentration 
M in.  Required 
Reduction
Param eter 
M in.  Required 
Reduction
USEPA M CL 
USEPA M CL 
Standard No. 53: Health Effects 
% Reduction 
Effluent 
Influent 
Average 
% Reduction 
Effluent 
Param eter 
Influent Challenge Concentration 
Influent 
Average 
UKF8001AXX
Specifications
Service Flow Rate (Maximum) ..................................... 0.78 GPM (2  9 L/min)
Rated Service Life UKF8001AXX-750 (Maximum) ....... 750 gallons/2839 liters
Maximum Operating Temperature ................................ 100° F / 38° C
Minimum  Pressure  Requirement ................................. 35 psi /241 kPA
Minimum Operating Temperature ................................. 33° F/1° C
Maximum Operating Pressure ..................................... 100 psi / 689 kPA
PentaPure Inc.
1000 Apollo Road
Eagan, Minnesota 55121-2240
651  450  4913
EPA EST #35917-MN-1
100834/B
  *
Tested using a flow rate of 0.78 gpm; pressure of 60 psig; pH of
7.5 + 0.5; temp. of 68° + 5° F (20° + 3° C)
 **
Measurement in Particles /ml. Particles used were 0.5 - 1
microns
***
NTU - Nephelometric Turbidity Units
General Use Conditions
Read this Performance Data Sheet and compare
the capabilities of this unit with your actual water
treatment needs.
DO NOT use this product where water is
microbiologically unsafe or of unknown qual-
ity without adequate disinfection before or
after the system. System certified for cyst
reduction may be used on disinfected water
that may contain filterable cysts.
USE ONLY WITH COLD WATER SUPPLY.
CHECK FOR COMPLIANCE WITH THE STATE
AND LOCAL LAWS AND REGULATIONS.
Tested and certified by NSF International against ANSI/NSF Standards
42 & 53 in models UKF8001AXX-750 for the reduction of:
Standard No. 42: Aesthetic
Effects
Taste and Odor Reduction
Chlorine Taste & Odor
Mechanical Filtration Unit
Particulate Reduction Class 1
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead, Atrazine, Lindane, Mercury &
Toxaphene Reduction
Mechanical Filtration Unit
Cyst, Turbidity and Asbestos
reduction
The PuriClean® II retractable water filtration system uses a
UKF8001AXX replacement cartridge. Timely replacement of
filter cartridge is essential for performance satisfaction from
this filtration system.
Please refer to the applicable section of your Use & Care
Guide for general operation, maintenance requirements and
troubleshooting.
This system has been tested according to ANSI/NSF 42 and
53 for reduction of the substance listed above. The concentra-
tion of the indicated substances in water entering the system
was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in
ANSI/NSF 42 and 53.