Sony pfm-42x1 Zusätzliches Handbuch

Seite von 26
1-19
PFM-42X1/42X1N
7. Answer
(a) Normal message
Answer
Header
0x70
Normal answer header
Category
0xXX
Code table (7-a) : Normal code
Code table (7-a)
Normal code
0x00
Completed
0x01
Limit over
0x02
Limit under
0x03
Command cancelled
0x04
Command all enable
0x05
Fail
Normal response.
The packet was received normally, but the data value was over the upper
limit.
Forcedly the monitor adjusted the data to maximum value.
The packet was received normally, but the data value was under the lower
limit.
Forcedly the monitor adjusted the data to minimum value.
The packet was received normally, but the command was cancelled because
the function was not in adjustable mode, such as a function displayed as “—
—” in user menu.
The packet was received normally.
The command function is all enable.
The packet was received normally, but the command was cancelled .
Please retry.
(b) Error message
Answer
Header
0xE0
Error answer header
Category
0xXX
Code table (7-b) : Error code
Code table (7-b)
Normal code
0x00
No function error
0x02
Data number error
0x06
Mode error
0x07
Time out
Packet header,category or function codes do not exist in this protocol.
The data value in “Data num” area of received packet was different from the
function’s own data number.
The monitor is already in the service mode via remote commander
operation.
(The service mode through IR remote has priority over the serial remote
command. )
Packet communication are interrupted by some error, and did not return to
normal communication within 2 seconds.