NOTE:
The configuration settings given in the following steps are an example.
The actual configuration settings might vary depending on your requirements.
Verify that the 1-Port Gigabit Ethernet SFP Mini-PIM is installed on the device:
show chassis hardware
user@host > show chassis hardware
The following is a sample output of the command (SRX240 output shown, other
devices similar):
Hardware inventory:
Item             Version  Part number  Serial number     Description
Chassis                                AG1111AA7925      SRX240h
Routing Engine   REV 01   750-021793   PW7925            RE-SRX240H
  da0     999 MB  ST72682                                Nand Flash
  usb0 (addr 1)  DWC OTG root hub 0    vendor 0x0000     uhub0
  usb0 (addr 2)  product 0x6254 25172  vendor 0x058f     uhub1
  usb0 (addr 3)  ST72682  High Speed Mode 64218 STMicroelectronics umass0
FPC 0                                                    FPC
  PIC 0                                                  16x GE Base PIC
FPC 1                     750-029145   112009000278      FPC
  PIC 0                                                  1x GE SFP mPIM
FPC 2            REV 00   750-032730   AABC5081          FPC
  PIC 0                                                  1x GE High-Perf SFP 
mPIM
    Xcvr 0       REV 02   740-013111   9101465           SFP-T
FPC 3                     750-029145   062009000057      FPC
  PIC 0                                                  1x GE SFP mPIM
FPC 4                     750-029145   122009000061      FPC
  PIC 0                                                  1x GE SFP mPIM
    Xcvr 0       REV 01   740-011782   PBL0C3T           SFP-SX
Power Supply 0
NOTE:
In the example shown above, the output for the 1-Port SFP Mini-PIM
appears as 1X GE SFP mPIM, and the output for the 1-Port Gigabit Ethernet
SFP Mini-PIM appears as 1X GE High-Perf SFP mPIM.
Verify the status of the interface:
show interfaces terse
Assign the port an IP address, for example:
set interfaces ge-1/0/0 unit 0 family inet address interface address/destination prefix
Add or select a security zone; for example, Trust:
set security zones security-zone trust interfaces ge-1/0/0.0 host-inbound-traffic
system-services telnet
Add or select security zones for host inbound traffic protocol options, for example :
Copyright © 2012, Juniper Networks, Inc.