7
3. Electrical connection
Make sure that the voltage and capacity of the power line conform 
to the data shown on the plate located under the casing. 
Do not 
remove this plate for any reason.
The plug on the end of the supply cable and the wall socket must 
be the same type and conform to the current electrical system 
regulations. Check that the power line is adequately grounded.
On the power line, install an omnipolar cut-off device with contact 
cut-off distance greater than or equal to 
3 mm, located in an easily 
accessible position near the unit.
Do not use reducers, adapters or shunts.
If the power cable is replaced, the wire section on the new cable 
must not be less than 1.5 mm
(3 x 1.5 cable), keeping in mind 
that the end to be connected to the hob must have the ground 
wire (yellow-green) longer by at least 20 mm. Use only 
H05V2V2-F cable or similar which has a maximum temperature 
of 90°C. Any replacement needed should be carried out by a 
specialised technician who should make the mains connections 
according to the following diagram.
= brown
= blue
    = yellow-green
The manufacturer will not be liable for any damage to persons or 
property caused by non-observance of the above instructions or 
deriving from the tampering of even a single part of the hob.