2. Advance Check of the Case
Advance check before use
This Case has been the subject of thorough quality control for the parts 
during the manufacturing process and thorough function inspections 
during the assembly. In addition, a water pressure test is performed with 
a water pressure tester for all products to confirm that the performance 
conforms to the specifications.
However, depending on the carrying and storage conditions, the 
maintenance status, etc., the waterproof function may be damaged.
Before using, always perform the following advance checks.
Remove the O-ring
1 Open the Case.
For details about how to open the Case, see P.19 of this manual.
2 Insert the O-ring remover into the gap between the O-ring and O-ring 
groove wall.
3 Slip the tip of the inserted O-ring remover below the O-ring.
(Be careful not to scratch the O-ring groove with the tip of the O-ring 
remover.)
4 Lift the O-ring, pinch it with your fingertips and pull it out of the Case.
CAUTION:
If the advance test should show water leakage with normal handling, stop 
using the Case and contact your dealer or an Olympus service station.