Olympus PT-057 Gebrauchsanleitung

Seite von 32
EN 24
EN
Water Leakage Test
The final test after loading the camera is explained below. Always perform 
this test. It can be performed easily in a water tank or a bathtub. Confirm 
the operation of the different buttons. The required time is about 
5 minutes.
• At first, immerse the Case for only 3 seconds and check that no water 
enters the Case.
• Next, immerse the Case for 30 seconds and check that no water drop 
etc. has entered the Case.
• Then, immerse the Case for 3 minutes, operate all buttons and levers, 
and check the following:
- check that no water has entered the Case.
- check that the Case is not clouded.
- check that no water drop has entered the Case.
• If the inside of the Case becomes cloudy or there is a water drop, do the 
maintenance of the O-ring and perform the water leakage test again.
PT-057_EN.book  Page 24  Friday, November 21, 2014  10:13 AM