Trouble Conditions
 (cont’d)
 
 
Words or letters in parentheses (   ) are those that are displayed on Fixed-Word Display 
keypads. 
 
Other Trouble 
Displays 
 
 
 
*
 
Any “beeping” that 
accompanies a 
trouble display can 
be stopped by 
depressing any key 
on the keypad or by 
entering an OFF 
sequence (code + 
OFF) 
 
 
 
 
**
    
Not all systems use 
 wireless sensors. 
 
COMM. FAILURE 
Indicates that a failure has occurred in 
(or FC
the telephone communication portion of 
your system. CALL FOR SERVICE.  
 
SYSTEM LO BAT 
Indicates that a low system battery  
(or BAT with no 
condition exists.  Display is  
zone No.) 
accompanied by "beeping"* at the 
keypad. If this condition persists for 
more than one day (with AC present), 
CALL FOR SERVICE. 
 
LO BAT 
Indicates that there is a low battery 
zone descriptor 
condition in the wireless transmitter** 
(or BAT with 
number displayed (00 is RF keypad).  
zone No.) 
Accompanied by a single "beep"* (about 
once every 30 seconds) at the keypad.  
 
 
Either replace the battery yourself, or 
CALL FOR SERVICE.  If the battery is 
not replaced within 30 days, a CHECK 
display may occur.  
 
Rcvr Jam 
Wireless part of the system is experiencing
(or CHECK 90
RF interference which may impede 
reception from wireless sensors.** 
 
ALARM 1xx 
FAULT 1xx 
CHECK 1xx
 
(or 91
Indicates a communication problem 
between the control and a connected 
device (e.g., RF receiver, zone expander) 
where the “xx” indicates the device 
address. CALL FOR SERVICE. 
 
MODEM COMM  
(or CC
Indicates that the control is on-line with 
the Central Monitoring Station's remote 
computer.  
The control will not report system 
activity while on-line. Wait a few minutes 
— the display should disappear. 
 
BELL FAILURE 
Indicates that the wiring connection to  
(or CHECK 70
the external sounder is at fault (open or 
shorted). Accompanied by “beeping” at 
the keypad. CALL FOR SERVICE.