Honeywell Honeywell Security | Protect What Matters Most Betriebsanweisung

Seite von 64
 
 
– 13 – 
Entry/Exit Delays 
Entry/Exit Delays 
Entry/Exit Delays 
Entry/Exit Delays 
(Continued)
(Continued)
(Continued)
(Continued)
    
 
Exit Alarms
Exit Alarms
Exit Alarms
Exit Alarms 
Exit Error Conditions 
Whenever you arm the system, the exit delay begins. If an entry/exit door or interior 
zone is faulted before exit delay expires and remains faulted (e.g., exit door left open), 
the system sounds an alarm and starts the entry delay timer. If you disarm the 
system before the entry delay ends, the alarm sound stops and the message "ALARM 
CANCELED " or "CA" is displayed on the keypad, along with a zone number 
indicating the faulted zone. No message is sent to the Central Monitoring Station.   
 
To clear the exit error condition, the open zone must be made intact; to clear the 
display, enter your code plus OFF. 
 
If you do not disarm the system before the entry delay ends and the faulted zone 
remains open, the alarm sound continues and an "exit alarm" message is sent to the 
Central Monitoring Station (after the installer-programmed dial delay expires). The 
message "EXIT ALARM" or "EA" is displayed on the keypad, along with a zone 
number indicating the faulted zone. To stop the alarm, the system must be disarmed 
(your code plus OFF); to clear the display, enter your code plus OFF a second time. 
 
An “exit alarm” also results if an entry/exit door or interior zone is faulted within two 
minutes after the end of the exit delay. 
 
Your system may have been programmed for this feature to minimize false alarms sent to the Central 
Monitoring Station. Ask your installer if "Exit Alarm" is active in your system. If so, check this box.    
           
 
 
 
 
VISTA-10PSIA: The Exit Error condition works the same as described above, except that in 
addition to the “EXIT ALARM” message, a “zone alarm” message is also sent to the Central 
Monitoring Station. In addition, if an entry/exit door or interior zone is faulted within two 
minutes after the end of the exit delay, a “Recent Closing” condition occurs instead of the “exit 
alarm.” Refer to the next paragraph for details. 
 
“Recent Closing” Condition (VISTA-10PSIA only) 
A Recent Closing condition is similar to the Exit Error condition described above, but occurs if 
an entry/exit door or interior zone is faulted within two minutes after the initial exit delay 
expires. If you disarm the system within the two minutes, the alarm sound stops and the 
message "ALARM CANCELED " or "CA" is displayed on the keypad, along with a zone number 
indicating the faulted zone. No message is sent to the Central Monitoring Station. 
 
If you do not disarm the system within two minutes and the faulted zone remains open, the 
alarm sound continues and a “recent closing” and a “zone alarm” message are sent to the 
Central Monitoring Station (after the installer-programmed dial delay expires). The alarm 
message along with a faulted zone number  is displayed on the keypad. To stop the alarm, the 
system must be disarmed (your code plus OFF); to clear the display, enter your code plus OFF 
a second time.