Fire Alarm System (If Installed)
Fire Alarm System (If Installed)
Fire Alarm System (If Installed)
Fire Alarm System (If Installed)    
 
THIS SECTION APPLIES ONLY TO RESIDENTIAL SYSTEMS  
 
General 
Your fire alarm system (if installed) is on 24 hours a day, for 
continuous protection. In the event of an emergency, the strategically 
located smoke and heat detectors will sound their alarms and 
automatically send signals to your system, triggering a loud, 
interrupted pulsed sound* from the Keypad(s) and any external 
sounders. A FIRE message will appear at your Keypad and remain on 
until you silence the alarm (see below for silencing fire alarms).  
*
 
Temporal pulse sounding is produced for Fire alarms, as follows: 
 3 pulses–pause–3 pulses–pause–3 pulses–pause. . . , repeated. 
 
 
TYPICAL FIRE EMERGENCY  DISPLAYS
 
 
F I R E   0 1       M A S T E R  
B E D R O O M
 
 
01
01
01
01    
ALARM 
 
FIRE 
 
 
AC
 
 
 
 
ALPHA DISPLAY KEYPAD
 
 
FIXED-WORD KEYPAD
 
 
Silencing  
Fire Alarms and 
Clearing Memory 
of Alarm 
1.  You can silence the alarm at any time by pressing the OFF key (the 
security code is not needed to silence fire alarms). To clear the 
display, enter your code and press the OFF key again (to clear 
Memory of Alarm). 
2.  If the Keypad's FIRE display does not clear after the second OFF 
sequence, smoke detectors may still be responding to smoke or heat 
producing objects in their vicinity. Investigate, and should this be 
the case, eliminate the source of heat or smoke. 
3.  If this does not remedy the problem, there may still be smoke in the 
detector. Clear it by fanning the detector for about 30 seconds. 
When the problem has been corrected, clear the display by 
entering your code and pressing the OFF key.  
 
Smoke Detector 
Reset 
Depending on the type of smoke detectors in your system, it may be 
necessary to "reset" the smoke detectors after a fire alarm has been 
turned off. Check with your installer. This "reset" is accomplished at a 
keypad, as follows:   
Enter security code*, then press the [1] key (* except “arm only” user). 
NOTE: During smoke detector reset, “FAULT xx” appears (about six 
seconds) and should disappear if the detector is clear.