Weissgauff HV 640 B Benutzerhandbuch

Seite von 20
After setting  cooking stage  “9“ Automatic  parboiling is activated 
by pressing at the right slider sensor. “A” appears on the display 
immediately.  
Now the required onboiling  stage is selected via Slider area. The 
“A”  symbol  appears  after  3  sec.  upon  releasing  the  key  -
alternating  with the onboiling  stage (500  msec. “A” and 1.5 sec. 
onboiling stage).  
The  onboiling  stage  may  be  changed  within  15  sec  after 
activation  without  switching  off  the  parboiling  boost.  Therefore, 
the cooking zone is to be selected and the relevant cooking zone 
is to be set afterwards.  
In case of a selection after 15 sec a lower cooking stage may be 
set; automatic onboiling is switched off.  
a  higher  onboiling  stage  may  be  selected;  this  leads  to  the 
parboiling  time  being  automatically  brought  in  line  with  the 
currently selected onboiling stage  
 
Multi Circuit Activation (Optional) 
The control unit may trigger – depending on the type – dual circuit 
or triple circuit. Multi  Circuits are  switched automatically on  after 
activating a cooking zone.  
Activation/Deactivation of dual circuit HL  
By  actuating  the  dual-circuit  key  “3”  the  respective  double  or 
outer circuit is deactivated. Re-actuating the dual-circuit  key “3” 
activates the outer circuit again, 
An  active  double or outer circuit  is  also  shown  by  the  assigned 
LED “11” is statically illuminated.  
Activation/Deactivation of triple circuit HL 
For triple-circuit the following operation procedure is provided:  
-By actuating the  multi-circuit key “3” the respective double and 
triple circuits of an active cooking zone are deactivated.  
-Re-actuating  the  multi  circuit  key  “3”  activates  the  first  outer 
circuit and the assigned LED “11” illuminates again.  
-A  second  actuation  of  the  multi  circuit  key  “3”  activates  the 
second outer circuit and the assigned LED “11” illuminates again.  
 
Residual Heat  
The  determination  of how  long a cooking zone has residual heat 
after operation and switch off – which may lead to burnings when 
contacting – is calculated.  
Status is calculated depending on:  
Selected power stage (from “0” to “9”)  
On/Off Time of the Relays  
 
The  residual  heat  indication  of  each  cooking  zone  remains 
activated until the calculated temperature is smaller than + 60 °C.  
 
Automatic Switch-off (Operating Time Limitation)  
For  each  activated  cooking  zone  a  max.  operating  time  is 
defined.  The  max.  operating  time  is  depending  on  the  selected 
cooking stage. After the expiration of the max. operating time the 
cooking zone is automatically switched off.  
Each actuation of the cooking zone status (changing the cooking 
level etc.) resets the count-down timer to the initial starting value.  
Timer  settings take priority  vs. operating time  limitations for  high 
cooking stage setting.  
Protection against unintentional activation  
The  electronic  system  cuts  off  automatically  in  case  of  an 
identified  permanent  use  of  keys  for  about  10  seconds.  The 
control  unit  releases  an  audible  signal  for  10  sec  of  the 
malfunction  (period:  1000  msec.,  500  msec.  ON)  and  the  error 
code “E  R 0 3” flashes on the  display (0.5 s ON  0.5s OFF). If the 
permanent  actuation  exceeds  10  sec.,  only  the  error  code  “ER 
03“  keeps  flashing  as  long  as  the  malfunction  occurs  and  is 
identified as such. In case the cooking zone is at stage “hot“ the 
[H] symbol alternates with the error code (0.5 sec Symbol 0.5 sec 
“H“).  
Water  sprinkled  on the  glass surface  does  not always  lead to  a 
key  actuation  and  cannot  be  surely  detected.  (  After  wiping  the 
glass  covering  the  keys,  all  keys  are  ready  for  operation  in  no 
time).  
If  no  cooking  zone  is  activated  within  20  sec  after  pressing 
POWER ON, the control unit is reset to Off-mode (black displays).  
 
Key Lock (Optional)  
The actuation of the key lock key “4”  in the wait or  active mode 
locks  the  keyboard  and  the  assigned  key-lock  LED  “7”  is 
statically  illuminated.  Here,  the  actuation  times  of  the  key-lock 
key have to be taken into account. The control continues to work 
in  the  set  mode,  but  may  no  longer  be  operated  with  any  key, 
except the key-lock key itself or the on/off key “1”.  
 
The switching OFF with the on/off key “1” is also possible in the 
locked  condition.  The  assigned  key-lock  LED  “7”  fades  when 
switching  off  the  control  The  key-lock  function  included  LED  is 
active  again  when  switching  on  (in  wait  mode  10  s)  until  this  is 
deactivated  by  a  repeated  actuation  of  the  key-lock  key.  The 
activation/deactivation of the key-lock function in the off mode is 
not possible.  
When  programmed  timers  expire,  the  respective  timer  alarms 
may be confirmed by actuating any key without needing to unlock 
the control.  
The  repeated  actuation of the  key-lock  key  in the wait or active 
mode  unlocks  the  keyboard  and  the  assigned  key-lock  LED 
fades. All sensor keys may be operated as usual again.  
 
Acoustic Feedback (Buzzer)  
The following activities occurring  during operation of the TC unit 
are fed back audibly via a buzzer:  
Short single tone for regular actuation of a key  
Longer, intermittent tone for permanent use of keys over a longer 
period of time (≥ 10 sec)  
Expiry of the timer  
 
Timer-function (optional)  
The timer function is available in two types:  
-Stand-alone-timer  1..99  min:  Audible  signal  with  timing.  This 
function  can  only  be activated  as  long  as  no cooking zone  is  in 
operation  (all  stages  =  0).  Is  any  cooking  zone  started  with 
operation (level >0) than the stand alone timer keeps in operation. 
If the timer shall be used to cut off a cooking zone (see cooking 
zone  timer)  then  the  control  must  first  be  switched  off  (power 
sensor) and switched on again.