Cisco Cisco Expressway Wartungshandbuch

Seite von 394
Field
Description
Usage tips
Port on B2BUA 
for transcoder 
communications
The IP port used on the B2BUA for 
communicating with the transcoders. Default is 
65080.
All transcoder communications are carried 
out over TLS.
Use transcoder 
policy rules
Specifies whether the transcoder policy rules 
are used to control access to the transcoders. 
Default is No.
If Enable transcoders for this B2BUA is 
Yes, then all calls are routed via the 
transcoders by default. 
If transcoder resources need to be 
reserved for specific types of calls, you 
can use this option to limit the types of 
calls that are routed via the transcoders. 
Set this option to Yes and then define the 
required 
TURN
 section:
Offer TURN 
services
Controls whether the B2BUA offers TURN 
services. Default is No.
This is recommended for calls traversing a 
Microsoft Lync Edge server.
To configure the associated 
TURN servers, click 
Advanced settings
: you should only modify the advanced settings on the advice of Cisco customer support.
Encryption
Controls how the B2BUA handles encrypted 
and unencrypted call legs.
Required: both legs of the call must be 
encrypted.
Auto: encrypted and unencrypted combinations 
are supported.
The default is Auto.
A call via the B2BUA comprises two legs: 
one leg from the B2BUA to a standard 
video endpoint, and one leg from the 
B2BUA to the Lync client. Either leg of the 
call could be encrypted or unencrypted. 
A setting of Auto means that the call can 
be established for any of the encrypted 
and unencrypted call leg combinations. 
Thus, one leg of the call could be 
encrypted while the other leg could be 
unencrypted.
B2BUA media 
port range 
start/end
The port range used by the B2BUA for handling 
media. Default range is 56000–57000.
Ensure that the port range does not 
overlap with other port ranges used by this 
Expressway or this Expressway's TURN 
server.
Hop count
Specifies the Max-Forwards value to use in SIP 
messages. Default is 70.
 
Session refresh 
interval
The maximum time allowed between session 
refresh requests for SIP calls. Default is 1800 
seconds.
For further information see the definition of 
Session-Expires in 
.
Minimum 
session refresh 
interval
The minimum value the B2BUA will negotiate for 
the session refresh interval for SIP calls. Default 
is 500 seconds.
For further information see the definition of 
Min-SE header in 
Port on B2BUA 
for Expressway 
communications
The port used on the B2BUA for communicating 
with the Expressway. Default is 65070.
 
Port on B2BUA 
for Lync call 
communications
The port used on the B2BUA for call 
communications with the Microsoft Lync server. 
Default is 65072.
 
Cisco Expressway Administrator Guide (X8.5)     
Page 191 of 394
Applications