Cisco Cisco Packet Data Gateway (PDG) Installationsanleitung

Seite von 317
  Applying Power and Verifying the Installation 
Verifying the Installation  ▀   
 
ASR 5000 Installation Guide  ▄  
 
   
175 
Figure 55.  Card-Level Status LEDs for the Optical (ATM) Line Card 
 
Optical (ATM) Line Card Run/Fail LED States 
The Run/Fail LED on the ATM line card indicates the overall status of the card. These LEDs are illuminated steady 
green for normal operation. 
If the LED is not green, use the troubleshooting information in the table to diagnose the problem. 
Table 69. 
Optical (ATM) Line Card Run/Fail LED States 
Color
 
Description
 
Troubleshooting
 
Green  Card powered with no errors detected 
None needed.  
Red 
Card powered with error(s) detected 
Errors were detected during the POSTs. It is likely that the errors were 
logged to the system's command line interface during the boot process. 
Refer to the System Administration Guide for troubleshooting information. 
None 
Card is not receiving power 
Verify that the POWER LEDs on the PFUs are green. If they are not, refer 
to 
 for troubleshooting information. 
Verify that the power source is supplying ample voltage and current to the 
chassis. 
Verify that the card is properly installed per the instructions in this 
document. 
If all of the above suggestions have been verified, it is possible that the line 
card is not functional. Please contact your service representative.