Cisco Cisco Packet Data Gateway (PDG) Installationsanleitung

Seite von 317
Replacing Upper or Lower Fan Tray   
▀  What to do with the Failed Fan Tray 
 
 
▄  ASR 5000 Installation Guide 
238 
   
Step 3 
Verify that the particulate filter is securely in place. Its front should be flush with the front of the fan tray assembly and 
its tab should be lowered to keep it in place. 
 
Step 4 
Replace the fan tray bay cover/EMI shield. The perpendicular tabs on the cover should face away from the chassis and 
be positioned at the bottom. Use a Phillips #1 screwdriver to hand tighten the four captive screws in an alternating 
pattern – upper left, lower right, lower left, upper right (5 inch-lbf, 0.5 N-m). Do NOT use an electric or pneumatic 
torque driver to tighten these screws.
 
Step 5 
Replace the lower plastic bezel by aligning it over the bezel mounts that protrude from the fan tray bay cover and 
snapping the it in place. 
What to do with the Failed Fan Tray 
If the failed fan tray is still under warranty, return it to the vendor for repair.  
If the failed fan tray is out of warranty, contact Cisco to determine if it can be sent in for repair at an additional cost.  
Important:
  Disposal of this product should be performed in accordance with all national laws and regulations. 
Refer to the support area of http://www.cisco.com for up-to-date product documentation pertaining to installation, 
configuration, and maintenance. A valid username and password is required to use this site. Please contact your local 
sales or service representative for additional information. 
Important:
  For additional information on the RMA process, see the RMA Shipping Procedures appendix.