Cisco Cisco Packet Data Gateway (PDG) Installationsanleitung

Seite von 317
Environmental Specifications   
▀  Operating and Storage Parameters 
 
 
▄  ASR 5000 Installation Guide 
282 
   
Operating and Storage Parameters 
Use the following information to plan your network installation for the ASR 5000 platform. 
Table 106.  Temperature, Humidity and Altitude Recommendations 
Temperature
 
Operating 
0 degrees C to +55 degrees C 
Storage 
-40 degrees C to +70 degrees C 
Humidity
 
Operating 
20 to 80 percent non-condensing 
Storage 
10 to 95 percent non-condensing 
Altitude
 
Operating 
197 ft. (60m) below to 13,123 ft. (4,000m) above sea level 
Non-operating 
197 ft. (60m) below to 49,212 ft. (15,000m) above sea level 
 
Supported Environmental Standards 
The system has been successfully tested against the following environmental standards: 
 
Operational Thermal, Operating Conditions - GR-63 Criteria [72, 73] 
 
Airborne Contaminants, Indoor Levels - GR-63 Criterion [125] 
 
Operational Thermal, Short-term Conditions - GR-63 Criteria [72, 73] 
 
Storage Environments, and Transportation and Handling - GR-63 Criteria [69-71, 107-109, 124] 
 
Earthquake Zone 4 - GR-63 Criteria [110-112, 114, 115, 117, 119] 
 
Airborne Contaminants, Outdoor Levels - GR-63 Criteria [126, 127] 
 
Altitude - GR-63 Criteria [74, 76] 
 
Thermal Heat Dissipation - GR-63 Criteria [77-79] 
 
Acoustic Noise - GR-63 Criterion [128] 
 
ESTI 300 019 - Environmental conditions and environmental tests for telecommunications equipment