  Installing the Update
Step 17
Reapply access control policies to all devices.
Caution
Do not reapply your intrusion policies individually; you must reapply all access control policies 
completely.
Applying an access control policy may cause a short pause in traffic flow and processing, and may also 
cause a few packets to pass uninspected. For more information, see the FireSIGHT System User Guide.
Step 18
If a patch for Version 5.3.1.5 is available on the Support site, apply the latest patch as described in the 
FireSIGHT System Release Notes for that version. You must update to the latest patch to take advantage 
of the latest enhancements and security fixes.
Note
After updating your Defense Center, note that the apply icon for device changes is enabled and turns 
green to indicate changes that need to be reapplied to your registered devices.
Updating Cisco ASA with FirePOWER Services
After you update your Defense Centers to Version 5.3.1.5, use them to update the ASA FirePOWER 
devices they manage.
A Defense Center must be running at least Version 5.3.0.1 to update its ASA FirePOWER devices to 
Version 5.3.1.5.
Updating ASA FirePOWER devices is a two-step process. First, download the update from the Support 
site and upload it to the managing Defense Center. Next, install the software. You can update multiple 
ASA FirePOWER devices at once, but only if they use the same update file.
For the Version 5.3.1.5 update, all ASA FirePOWER devices reboot. Depending on how your 
ASA FirePOWER devices are configured and deployed, the update process may also affect traffic flow 
and link state. For more information, see 
Caution
Before you update an ASA FirePOWER device, use its managing Defense Center to reapply the 
appropriate access control policy to the ASA FirePOWER device. Otherwise, the ASA FirePOWER 
device update may fail.
Caution
Do not reboot or shut down your appliances during the update until after you see the login prompt. The 
system may appear inactive during the pre-checks portion of the update; this is expected behavior and 
does not require you to reboot or shut down your appliances.
To update Cisco ASA with FirePOWER Services:
Step 1
Read these release notes and complete any required pre-update tasks.
For more information, see 
.
Step 2
Update the software on the ASA FirePOWER devices’ managing Defense Center; see