Cisco Cisco Catalyst 6500 Series Firewall Services Module Fehlerbehebungsanleitung

Seite von 5
FWSM(config)#fail lan unit {primary|secondary}
Enter this command in the system execution space to configure the failover VLAN interface for
multiple context mode:
primary(config)#failover lan interface interface_name vlan vlan
3. 
Enter this command to set the IP address of the failover interface:
primary(config)#failover interface ip failover_interface ip_address mask standby 
ip_address
4. 
Enable failover:
FWSM(config)#failover
This output shows an example:
FWSM(config)#failover lan unit secondary
FWSM(config)#failover interface ip fover 10.1.1.10 255.255.255.0 standby 10.1.1.11
FWSM(config)#failover LAN Interface fover vlan 50
FWSM(config)#failover
This output appears:
Detected an Active mate.  Switching to Standby
Beginning configuration replication from mate.
This unit is in syncing state. 
End configuration replication from mate.
5. 
Confirm Setup and Configuration
The Output Interpreter Tool (registered customers only) (OIT) supports certain show commands. Use the OIT
to view an analysis of show command output.
Issue this show command:
fwsm(config)#show failover
Failover On
Failover unit Primary
Failover LAN Interface fover Vlan 150
Unit Poll frequency 15 seconds
Interface Poll frequency 15 seconds
Interface Policy 50%
Monitored Interfaces 249 of 250 maximum
Config sync: active
Last Failover at: 10:58:08 Apr 15 2004
        This host: Primary − Standby 
                Active time: 0(sec)
                admin Interface inside (10.6.8.91): Normal 
                admin Interface outside (70.1.1.2): Normal 
        Other host: Secondary − Active 
                Active time: 2232 (sec)
                admin Interface inside (10.6.8.100): Normal 
                admin Interface outside (70.1.1.3): Normal 
Check to see that 
This host
 is in 
standby
. Also check to see if you can ping devices off your interfaces
from the FWSM. If you want the new device to become active, use the no active failover command to force
failover.
Enter this command on the active module to failover to the standby module: