Release Notes for the Catalyst 6500 Series and Cisco 7600 Series Firewall Services Module, Software Release 4.0(x)
Resolved Caveats
•
CSCtc73075
With Skinny inspection enabled, some returning traffic does not get through. Therefore, phone calls
only get unidirectional voice (the flow does not go through from outside to inside). This issue
appears more frequently with a large number of calls.
only get unidirectional voice (the flow does not go through from outside to inside). This issue
appears more frequently with a large number of calls.
Note
This issue is not present in 4.0(2) and lower.
Workaround: None.
•
CSCte69628
With a large number of ACEs configured (for example, 51,000 for single mode or 14,000 for
multiple mode), if you disable access list optimization, the console might hang for 5 to 6 minutes.
multiple mode), if you disable access list optimization, the console might hang for 5 to 6 minutes.
Workaround: None. If you wait, the console will return.
•
CSCte89422
When using failover, if you copy new configurations with access list and object group changes to
multiple contexts simultaneously, it can result in failed synchronization to the standby unit.
multiple contexts simultaneously, it can result in failed synchronization to the standby unit.
Workaround: Copy context configurations one at a time.