Cisco Prisma II 1310 nm HDTx Transmitters Installationsanleitung

Seite von 125
A-4 
Module Parameter Descriptions 
78-4010846-01 Rev D 
Alarm Parameters 
Introduction 
The following table describes the alarm parameters for this module. Alarm limits are 
dependent on module type and configuration. 
 
Alarm Name 
(LCI) 
ICIM 
Abbrev. 
Function 
Threshold Values 
Hys-
teresis 
Major 
Low 
Minor 
Low 
Minor 
High 
Major 
High 
Laser Bias 
Current * 
LasBias 
Laser bias 
current 
-32 A 
-32 A 
-0.1 A 
-0.01 A  0.001A 
Optical Input 
Power * 
InPwr 
Optical input 
power 
-15.0 
dBm 
-5.0 
dBm 
20.0 
dBm 
45.0 
dBm 
1.0 
dBm 
Optical 
Output 
Power * 
OutPwr 
Optical output 
power 
-1.0 
dBm 
-0.7 
dBm 
0.7 
dBm 
1.0 
dBm 
0.1 
dBm 
Laser  
Temperature 
LasTemp  Laser 
temperature 
-20.0°C  -15.0°C  35.0°C  40.0°C  1.0°C 
Laser 
Enabled 
Status 
Enable 
Module on or 
off 
Internal 
Power 
Supply 
Status 
IntPs 
Power supply 
fault 
 
* These are user alarms whose limits can be changed by the user. All other alarms are 
module alarms whose limits are set at the factory and cannot be changed by the user.