Cisco Cisco D9824 Advanced Multi Decryption Receiver Installationsanleitung

Seite von 416
 
 
 
Setting up Input Information 
 
 
163 
 
4  In the  Direct Delay field, set the time to switch from primary to backup data port 
after the system detects a failure, in a range  from 0 to 10000 milliseconds. 
5  In the  Revertive Delay field, set the time to wait when  reverting  back to the 
primary port once all the triggers  for the primary  port are back to normal again, 
in a range  from 0 to 30 seconds. 
Note: If Non-Revertive  is selected as the  Type, this field does not apply. 
6  For the  Trigger, select the program-related  conditions  that will trigger  the MPEG 
over  IP input redundancy  switchover  to the backup port. check the  AV Loss
PMT Loss, or PCR Loss check box to detect the status of the audio/video, PMT, 
or PCR loss for the program entry being  decoded.   
The Link Loss and TS Loss fields are non-editable.  By default, Ethernet  (Link) 
loss and transport stream loss will always trigger  a redundancy  switchover  to 
the backup port. 
Note: If Revertive  is selected as the Type, and all the triggers  are selected, it will 
fail over  to the backup port when  any of the triggers  occur and the backup port 
has valid content. However,  it will  not attempt to revert  back to the primary  port 
when  the primary port is available again. It will remain  on the backup port. This 
avoids the constant switching  between  the two ports since the incoming  packet 
streams cannot be validated until the switch is made.  
7  Click Apply
 
Viewing the Current IP Input Status 
The Current Input Status area displays the current  IP status. 
 
The following  table describes  the Current  Input Status information  displayed: 
Parameter 
Description 
Active  Input 
Indicates  the currently  selected  input source  (RF1, RF2, RF3, 
RF4, ASI, or  IP).