Chapter 6    Service and Maintenance 
 
 
 
286 
 
D9824 Alarm Messages 
The Alarm LED on the front panel indicates whether  the unit has triggered  an alarm 
or warning.  A solid red signal  for five seconds indicates a warning,  and a flashing 
red signal indicates an alarm. For more  information,  see  About the Front  Panel (on 
page 36). 
The status of the D9824 receiver  and its immediate surroundings  is reported  to the 
front panel in the form of messages and alarms. You can enable  or disable messages 
in the Alarm/Warning  settings. 
The following  table shows an alphabetical list of the available messages and their 
default alarm status. The Set Messages and Clear Messages  are displayed in the 
Warning  History when  the messages are set or cleared respectively. 
Note: Only alarm conditions  can be used to trigger  rear panel relays to control 
external  alarm equipment.  Warnings  are not associated with relay  operation. 
It is recommended  that you collect the debug support data prior  to contacting Cisco 
customer support for any D9824 issues. 
 
Alarms 
Alarm 
Message 
Type 
Message 
Cause/Remedy 
Description 
Severity  ID 
PSB  non-
compliant 
Set 
PROD incomplete 
or PSB  non-
compliant 
Cause: Production 
Access  Reset 
command  was  not 
issued  after 
production 
programming  was 
completed. 
Remedy: The 
Access  Reset 
command  should 
be issued  by the 
user with  PROD 
credentials  if the 
device has  not yet 
been shipped  to 
the customer. 
Otherwise,  the 
customer  must 
reset credentials 
using the front 
panel. 
Device is in the 
WEAK  state 
after 
production 
programming 
is complete. 
Major 
900