Cisco Cisco FirePOWER Appliance 7115

Seite von 2442
Version 5.3
Sourcefire 3D System User Guide
297
Managing Devices
Editing Device Configuration
Chapter 5
3. Click Device.
The Device tab appears.
TIP!
For stacked devices, you edit the advanced device settings for the stack 
on the Stack page of the appliance editor.
4. Next to the Advanced section, click the edit icon (
).
The Advanced pop-up window appears.
5. Optionally, select Automatic Application Bypass if your network is sensitive to 
latency. Automatic Application Bypass is most useful in inline deployments. 
For more information, se
6. When you select the Automatic Application Bypass option, you can type a 
Bypass Threshold in milliseconds (ms). The default setting is 3000 ms and the 
valid range is from 250 ms to 60,000 ms.
7. Optionally, select the Inspect Local Router Traffic check box to inspect 
exception traffic when deployed as a router.
8. Optionally, configure fast-path rules. For more information, see 
9. Click Save.
Your changes are saved. Note that your changes do not take effect until you 
apply the device configuration; se