Cisco Cisco 2600 3600 3700 Series 36-Port 10 100 EtherSwitch Modules Fehlerbehebungsanleitung
2-33
Cisco Gigabit Ethernet Switch Module for the HP p-Class BladeSystem System Message Guide
380260-002
Chapter 2 Message and Recovery Procedures
PHY Messages
Error Message PHY-4-EXCESSIVE_ERRORS: Excessive FCS, data, or idle word errors found
on interface [chars].
on interface [chars].
Explanation
This message means that the system detected excessive frame check sequence (FCS),
data word, or idle word errors on the specified interface. [chars] is the interface.
Recommended Action
Enter the show interface privileged EXEC command
on the specified
interface, and check for cyclic redundancy check (CRC) and other input errors. If errors are
excessive, enter the shutdown interface configuration command and then the no shutdown interface
configuration command to reset the interface.
excessive, enter the shutdown interface configuration command and then the no shutdown interface
configuration command to reset the interface.
Error Message PHY-4-MODULE_DUP: SFPs in [chars] and in [chars] have duplicate
vendor-id and serial numbers.
vendor-id and serial numbers.
Explanation
The SFP module was identified as a Cisco SFP module, but its vendor ID and serial
number match that of another SFP module in the system. The first [chars] is the interface in which
the SFP module is installed, the second [chars] is the interface where the duplicate SFP module is
installed.
the SFP module is installed, the second [chars] is the interface where the duplicate SFP module is
installed.
Recommended Action
yay the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact HP technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting HP, see the
look for similar reported problems. If you still require assistance, contact HP technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting HP, see the
.
Error Message PHY-4-SFP_NOT_SUPPORTED: The SFP in [chars] is not supported
Explanation
This message means that this small form-factor pluggable (SFP) module type is not
supported on this switch. [chars] is the interface.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact HP technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting HP, see the
look for similar reported problems. If you still require assistance, contact HP technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting HP, see the
.
Error Message PHY-4-UNSUPPORTED_TRANSCEIVER:Unsupported transceiver found in
[chars]
[chars]
Explanation
The SFP module was identified as a unsupported, non-Cisco SFP module. [chars] is the
unsupported module.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact HP technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting HP, see the
look for similar reported problems. If you still require assistance, contact HP technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting HP, see the
.