Cisco Cisco 2600 3600 3700 Series 36-Port 10 100 EtherSwitch Modules Fehlerbehebungsanleitung

Seite von 92
   
2-33
Cisco Gigabit Ethernet Switch Module for the HP p-Class BladeSystem System Message Guide
380260-002
Chapter 2      Message and Recovery Procedures
PHY Messages
Error Message PHY-4-EXCESSIVE_ERRORS: Excessive FCS, data, or idle word errors found 
on interface [chars].
Explanation
This message means that the system detected excessive frame check sequence (FCS), 
data word, or idle word errors on the specified interface. [chars] is the interface.
Recommended Action
Enter the show interface privileged EXEC command
 
on the specified 
interface, and check for cyclic redundancy check (CRC) and other input errors. If errors are 
excessive, enter the shutdown interface configuration command and then the no shutdown interface 
configuration command to reset the interface. 
Error Message PHY-4-MODULE_DUP: SFPs in [chars] and in [chars] have duplicate 
vendor-id and serial numbers.
Explanation
The SFP module was identified as a Cisco SFP module, but its vendor ID and serial 
number match that of another SFP module in the system. The first [chars] is the interface in which 
the SFP module is installed, the second [chars] is the interface where the duplicate SFP module is 
installed.
Recommended Action
yay the message exactly as it appears on the console or in the system log. 
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to 
look for similar reported problems. If you still require assistance, contact HP technical support and 
provide the representative with the gathered information. For more information about the online 
tools and about contacting HP, see the 
.
Error Message PHY-4-SFP_NOT_SUPPORTED: The SFP in [chars] is not supported 
Explanation
This message means that this small form-factor pluggable (SFP) module type is not 
supported on this switch. [chars] is the interface.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. 
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to 
look for similar reported problems. If you still require assistance, contact HP technical support and 
provide the representative with the gathered information. For more information about the online 
tools and about contacting HP, see the 
.
Error Message PHY-4-UNSUPPORTED_TRANSCEIVER:Unsupported transceiver found in 
[chars]
Explanation
The SFP module was identified as a unsupported, non-Cisco SFP module. [chars] is the 
unsupported module.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. 
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to 
look for similar reported problems. If you still require assistance, contact HP technical support and 
provide the representative with the gathered information. For more information about the online 
tools and about contacting HP, see the 
.