Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installationsanleitung

Seite von 12
 
4019330 Rev C 
 
Product Description 
 
Product Description 
Overview 
The FLI Module acts as the interface between an external RF source and the Model 
GS7000 Node. 
The RF signal enters the Model GS7000 Node though port F2 in the node housing 
lid.  An RF cable assembly is provided to route the signal from port F2 to the input 
connector on the FLI Module.  (Port F1 entry is optional, but requires a shorter RF 
cable.)  The FLI Module accepts the RF signal through a female F-type push-on 
connector on the top cover of the module housing and routes the signal to the OIB 
through a signal pin. 
The FLI Module is designed to be mounted in the "RCVR 4" position on the OIB in 
the node. 
An RF test point on the module provides a sample of the RF signal at -20 dB for level 
monitoring. 
Note:  A special "Local Injection" version of the 1x2 Redundant FCM must be 
installed in the node to facilitate the operation of the FLI Module. 
 
Technical Specifications 
The FLI Module meets the following technical specifications. 
 
Forward Injection Port 
Performance 
Units  7.5 dB I/S EQ with 
1.5 dB I/S Pad 
Notes 
Operational Gain (minimum)  dB 
19.5 
Frequency Response 
dB 
±0.5 
 
Internal Tilt (±1 dB) 
dB 
14.5 
Input Return Loss 
dB 
16 
Notes: 
1  
Forward operational gain is for station from forward injection port to node RF 
output port with 0 dB pad in OIB, 1x2 Redundant Injection FCM, 1.5 dB 
interstage (I/S) pad, 7.5 dB linear I/S EQ, factory select output pad.  Includes 
OIB losses; ~ 2.25 dB loss through the FLI Module and RF cable, and ~ 15 dB loss 
through the FCM. 
2  Internal tilt is "Linear" tilt and is primarily due to an on-board fixed equalizer 
and a factory configured 7.5 dB linear I/S EQ. 
3  Input Return Loss specified for Forward Injection port.