Cisco Cisco Packet Data Gateway (PDG) Wartungshandbuch

Seite von 935
G-CDR and Enhanced G-CDR  Field Reference Tables   
▀  CDR Fields Supported in eG-CDRs 
 
▄  Cisco ASR 5000 Series AAA Interface Administration and Reference 
OL-23000-01   
List of Service Data Volumes 
List of Service Data Volumes
 
Rating group 
M  This is the service flow identity and has to be used for differentiated evaluation of user‘s traffic. Also 
known as content-id. 
Charging Rulebase 
name 
M  The name of the Rulebase used for charging This is the group name of charging rules. 
Result Code 
O  The result code AVP This contains the result code after the interconnection with the CRF. 
Local Sequence 
number 
M  A per service data container sequence number. It starts from 1 for each service, increasing by 1 for 
each service date container generated for that service within the lifetime of this PDP session. 
Time of first usage 
M  The time stamp for the first IP packet to be transmitted for the service data flow referred to the 
current instance of Service Condition Change. 
Time of last usage 
M  The time stamp for the last IP packet to be transmitted for the service data flow referred to the current 
instance of Service Condition Change. 
Usage time 
M  The difference between ―time of first usage‖ and ―time of last usage‖. 
Service condition 
change 
M  The reason for closing the service data container for triggers like SGSN change, QoS change, RAT 
change, time and volume triggers, etc. 
QoS negotiated 
O  The negotiated QoS applied for the service data flow. 
sgsn-Address 
M  The valid SGSN IP address during the service data recording interval. 
SGSN PLMN 
identifier 
O  The valid SGSN PLMN ID during the service data recording interval. 
FBC Data volume 
uplink 
M  The number of octets transmitted during the use of the packet data services in the uplink direction. 
FBC data volume 
downlink 
M  The number of octets transmitted during the use of the packet data services in the downlink direction. 
Time of report 
M  A time stamp defining the moment when the service data container is closed. 
RAT Type 
O  The valid RAT type during the service data recording interval. 
Failurehandling 
Continue 
O  A Boolean expression included if the failure handling condition has been executed. 
Service Identifier 
O  The service identifier may designate an end user service, a part of an end user service or an arbitrarily 
formed group thereof. 
 
Notes: 
LOSDV related changes:  
  Time Quota mechanism: Contains two further subfields and is included if envelope reporting is required: 
  Time Quota Type identifies the mechanism by which time-based usage should be reported — as defined 
in TS 32.299. 
  Base Time Interval identifies the length of the base time interval, for controlling the reporting of time-
based usage, in seconds. 
  User location information will be included in the LOSDV container in the R7 eG-CDRs.