Cisco Cisco Gigabit Ethernet Switch Module (CGESM) for HP
15
Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class Release Notes, Cisco IOS Release 12.2(37)SE and Later
383623-009
Open Caveats
•
CSCsc26726
Sometimes interfaces Gi0/23 & Gi0/24 will not link up with another switch when the interface speed
is set to an explicit value instead of autonegotiated. This does not happen when a copper SFP is used
with interfaces Gi0/17 - Gi0/20.
is set to an explicit value instead of autonegotiated. This does not happen when a copper SFP is used
with interfaces Gi0/17 - Gi0/20.
The workaround is to autonegotiate the speed with the other device, or to use a different cable type.
Use a straight through cable for switch to switch connection, or a cross-over cable for switch to any
non switch device connection. If the other device is capable of auto MDIX even with speed not set
to auto, then use that. When an improper cable is used only one side of the connection needs to use
auto MDIX to achieve a link.
Use a straight through cable for switch to switch connection, or a cross-over cable for switch to any
non switch device connection. If the other device is capable of auto MDIX even with speed not set
to auto, then use that. When an improper cable is used only one side of the connection needs to use
auto MDIX to achieve a link.
•
CSCsd78044
When IGMP snooping is enabled and an EtherChannel member interface goes down, the switch
might stop forwarding multicast traffic on the EtherChannel. This problem occurs when the
EtherChannel interface is a member of a multicast group that is not directly connected (that is, the
multicast group that does not have the C flag set in the show ip mroute privileged EXEC command
output).
might stop forwarding multicast traffic on the EtherChannel. This problem occurs when the
EtherChannel interface is a member of a multicast group that is not directly connected (that is, the
multicast group that does not have the C flag set in the show ip mroute privileged EXEC command
output).
The workaround is to either disable IGMP snooping, or to use the clear ip mroute user EXEC
command to refresh all the routes.
command to refresh all the routes.
•
CSCsd85770
When you apply the mls qos trust dscp global configuration command to a port, this error message
might appear.
might appear.
Master sets trust failed, sets to untrust modetrust type update
failed on ifc GigabitEthernetx/x
Switch(config-if)#Tcam write failed trust dscp
%QOSMGR-4-COMMAND_FAILURE: Execution of slave:HQM_IDBTRUST_CMD
command failed on GigabitEthernetx/x
The workaround is to apply the sdm prefer qos global configuration command before you enter the
mls qos trust dscp global configuration command.
mls qos trust dscp global configuration command.
•
CSCsd86177
When you remove and reconfigure a loopback interface, it does not appear in the ifTable.
The workaround is to reload the switch.
•
CSCse03859
If the switch is in VTP server mode and VLANs with IDs greater than 255 (256 and above) are
created, DHCP snooping does not work properly on these VLANs.
created, DHCP snooping does not work properly on these VLANs.
The workaround is to put the switch in VTP transparent mode before creating the VLANs.
•
CSCse06827
When dynamic ARP inspection is configured on a VLAN, and the ARP traffic on a port in the VLAN
is within the configured rate limit, the port might go into an error-disabled state.
is within the configured rate limit, the port might go into an error-disabled state.
The workaround is to configure the burst interval to more than 1 second.