Chapter 5      Managing Cisco NGIPS for Blue Coat X-Series 
  Changing Application Monitoring Status
To change the Unique NAT
 ID: 
Step 1
From the Configuration Menu, select 
4 Configure the NAT ID 
to change the Unique NAT ID.
Step 2
When prompted, enter the unique NAT ID.
If there are multiple VAPs in the VAP group, enter the NAT ID for each VAP in the VAP group.
Step 3
From the Configuration Menu, select 
5 Exit
 to quit.
Changing Application Monitoring Status
Application monitoring tracks whether your VAPs are running and halts load balancing of new flows to 
VAPs with failed VAPs.
If application monitoring is enabled (the default) for a VAP group, the operational state for a VAP can 
be either 
up
 or 
down
. An operational state of 
up
 indicates that all the VAP are running. With application 
monitoring enabled, an operational state of 
down
 indicates that at least one of the VAP has failed, or that 
Cisco NGIPS for Blue Coat X-Series running on the VAP group was stopped manually.
If application monitoring is disabled, the X-Series platform displays the operational state as 
Not 
Monitored
 and sends flows to the VAP, regardless of the actual operational state.
You may want to disable application monitoring in a few situations, including:
  •
deployments where you are using more than one interface per VAP
In this situation, if you disable application monitoring and an interface fails, the X-Series platform 
continues to send flows to the VAP and the other interfaces on the VAP can continue their analysis. 
However, note that flows directed to the failed interface will not be analyzed. 
On the other hand, if you are taking advantage of the load balancing and redundancy benefits of the 
X-Series platform by deploying intrusion prevention on multiple identically-configured VAPs, you 
may want to leave application monitoring enabled. You may experience some packet loss as old 
flows directed to the degraded VAP time out, but the X-Series platform will load-balance new flows 
to the other VAPs in the VAP group.
  •
if you have deployed Cisco NGIPS for Blue Coat X-Series inline, and you need to stop the 
application on the VAP group
This avoids the situation where the X-Series platform halts traffic to the VAP group when you stop 
the application. Halting traffic in an inline deployment can cause a network outage.
To check and change application monitoring status:
Step 1
Check the application monitoring state by entering the following command:
show vap
-
group vap_group_name
where 
vap_group_name
 is the name of the VAP group where Cisco NGIPS for Blue Coat X-Series is 
installed.
Locate 
Application Monitoring (true/false):
 near the bottom of the output and ensure that state is
t
 
(for true)
Step 2
If application monitoring is disabled and you to enable it, enter the command:
configure vap-group vap_group_name application-monitor
Step 3
If application monitoring is enabled and you to disable it, enter the command:
configure vap-group vap_group_name no application-monitor